Echocardiographic measurement of cardiac output in rats

被引:72
作者
Slama, M
Susic, D
Varagic, J
Ahn, J
Frohlich, ED
机构
[1] Alton Ochsner Med Fdn & Ochsner Clin, Div Res, New Orleans, LA 70121 USA
[2] Univ Picardie, Fac Med, Lab Pharmacol & Physiopathol Cardiovasc, F-80054 Amiens, France
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2003年 / 284卷 / 02期
关键词
Doppler; blood volume changes;
D O I
10.1152/ajpheart.00653.2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The systematic evaluation of different transthoracic echocardiographic (TTE) methods to determine cardiac output (CO) and the effect of changes in intravascular volume on echocardiographically determined indexes of cardiovascular structure in the rat has not been documented. With the use of 11 Wistar rats, simultaneous echocardiographic and thermodilution measurements of CO were compared at baseline and after blood withdrawal or transfusion at 43 different levels of intravascular volume and using 10 different echocardiographic approaches. The best correlation (r = 0.93; P < 0.0001), least bias (-3 ml/min), and best precision (16 ml/min) between thermodilution and echocardiographic methods were obtained at the level of aortic annulus using pulsed Doppler. In conclusion, CO could be accurately assessed in rats using TTE and pulsed Doppler at the level of the aortic annulus. This annulus was demonstrated to remain stable, but pulmonary annulus, thoracic aorta, mitral valve, and left ventricular diameters were found to be more modifiable during volumic changes.
引用
收藏
页码:H691 / H697
页数:7
相关论文
共 18 条
[1]  
Bjornerheim R, 2001, Eur J Echocardiogr, V2, P78, DOI 10.1053/euje.2000.0050
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   DOPPLER ULTRASONIC MEASUREMENT OF CARDIAC-OUTPUT - REPRODUCIBILITY AND VALIDATION [J].
COATS, AJS .
EUROPEAN HEART JOURNAL, 1990, 11 :49-61
[4]   CARDIAC-OUTPUT BY DYE DILUTION IN CONSCIOUS RAT [J].
COLEMAN, TG .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (03) :452-455
[5]   Tissue Doppler Imaging differentiates physiological from pathological pressure-overload left ventricular hypertrophy in rats [J].
Derumeaux, G ;
Mulder, P ;
Richard, V ;
Chagraoui, A ;
Nafeh, C ;
Bauer, F ;
Henry, JP ;
Thuillez, C .
CIRCULATION, 2002, 105 (13) :1602-1608
[6]  
DESIMONE G, 1990, AM J HYPERTENS, V3, P688
[7]   Determination of aortic elastic modulus by pulse wave velocity and wall tracking in a rat model of aortic stiffness [J].
Marque, V ;
Van Essen, H ;
Struijker-Boudier, HAJ ;
Atkinson, J ;
Lartaud-Idjouadiene, I .
JOURNAL OF VASCULAR RESEARCH, 2001, 38 (06) :546-550
[8]   ECHOCARDIOGRAPHIC DETERMINATION OF STROKE VOLUME DURING RAPID ATRIAL-PACING AND VOLUME LOADING IN NORMAL RATS [J].
NAKAMURA, T ;
MATSUMURO, A ;
KURIBAYASHI, T ;
MATSUBARA, K ;
SHIMA, M ;
SHIMOO, K ;
KATSUME, H ;
NAKAGAWA, M .
CARDIOVASCULAR RESEARCH, 1992, 26 (08) :765-769
[9]   Echo Doppler assessment of left ventricular function in rats with hypertensive hypertrophy [J].
Ono, K ;
Masuyama, T ;
Yamamoto, K ;
Doi, R ;
Sakata, Y ;
Nishikawa, N ;
Mano, T ;
Kuzuya, T ;
Takeda, H ;
Hori, M .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (02) :109-117
[10]   ELECTROMAGNETIC FLOWMETRY IN ANESTHETIZED RATS [J].
PFEFFER, MA ;
FROHLICH, ED .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 33 (01) :137-+