Steric crowding effects on target detection in an affinity biosensor

被引:75
作者
Bonanno, Lisa M.
DeLouise, Lisa A.
机构
[1] Univ Rochester, Sch Med & Dent, Dept Biomed Engn, Rochester, NY 14642 USA
[2] Univ Rochester, Sch Med & Dent, Dept Dermatol, Rochester, NY 14642 USA
关键词
D O I
10.1021/la063659c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work quantifies the impact of steric crowding on whole antibody (Ab) receptor immobilization and target Ab detection and also demonstrates how the versatile biotin/streptavidin receptor immobilization system must be tuned to optimize target detection in designing biosensors. Results are demonstrated on a label-free optical biosensor fabricated from n-type macroporous porous silicon (PSi) with similar to 88-107 nm diameter pores. We employ a sandwich assay scheme comprising a linking chemistry (biotin/streptavidin) to attach biotinylated anti-rabbit IgG (receptor) to detect rabbit IgG (target). A "bottom-up" approach was taken to investigate each layer of the sandwich assay to optimize target binding. Steric crowding was observed to hinder subsequent layer binding for each layer in the sandwich (biotin, streptavidin, and receptor). Our results give definitive evidence that the onset of steric crowding within the biotin layer occurs at a surface coverage of 57%, which is much higher compared to that from published work on well-ordered self-assembled biotin monolayers on planar gold surfaces. This difference is attributed to the topographical heterogeneity of the PSi substrate. Streptavidin (SA) binding to surface-linked biotin was altered by preblocking the streptavidin binding sites with biotin. Through consistent trends in data, preblocking SA was shown to reduce steric crowding within the SA layer, which translated into increased receptor immobilization. The final detection range of rabbit IgG was 0.07-3 mg mL(-1) (0.4-17 ng mm(-2)), and binding specificity was demonstrated by employing an anti-chicken IgG control receptor. This study underlines the importance of considering binding avidity and surface topography in optimizing chip-based biosensors.
引用
收藏
页码:5817 / 5823
页数:7
相关论文
共 38 条
[1]  
Arwin H, 2000, PHYS STATUS SOLIDI A, V182, P515, DOI 10.1002/1521-396X(200011)182:1<515::AID-PSSA515>3.0.CO
[2]  
2-W
[3]  
Avrantinis SK, 2002, CHEMBIOCHEM, V3, P1229, DOI 10.1002/1439-7633(20021202)3:12<1229::AID-CBIC1229>3.0.CO
[4]  
2-X
[5]  
BETOZZIL CR, 2001, SCIENCE, V291, P2357
[7]   EFFECTS OF CORTICOSTEROIDS ON IMMUNITY IN MAN .1. DECREASED SERUM IGG CONCENTRATION CAUSED BY 3 OR 5 DAYS OF HIGH DOSES OF METHYLPREDNISOLONE [J].
BUTLER, WT ;
ROSSEN, RD .
JOURNAL OF CLINICAL INVESTIGATION, 1973, 52 (10) :2629-2640
[8]   A porous silicon optical biosensor: Detection of reversible binding of IgG to a protein A-modified surface [J].
Dancil, KPS ;
Greiner, DP ;
Sailor, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (34) :7925-7930
[9]   Steric considerations in the covalent binding of myoglobin to thin films [J].
Deckert, AA ;
Farrell, C ;
Roos, J ;
Waddell, R ;
Stubna, A .
LANGMUIR, 1999, 15 (17) :5578-5583
[10]   Cross-correlation of optical microcavity biosensor response with immobilized enzyme activity. Insights into biosensor sensitivity [J].
DeLouise, LA ;
Kou, PM ;
Miller, BL .
ANALYTICAL CHEMISTRY, 2005, 77 (10) :3222-3230