Increased variance of P wave duration on the electrocardiogram distinguishes patients with idiopathic paroxysmal atrial fibrillation

被引:76
作者
Andrikopoulos, GK [1 ]
Dilaveris, PE [1 ]
Richter, DJ [1 ]
Gialafos, EJ [1 ]
Synetos, AG [1 ]
Gialafos, JE [1 ]
机构
[1] Hippokrat Hosp, State Dept Cardiol, Athens, Greece
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2000年 / 23卷 / 07期
关键词
P wave variance; electrocardiogram; idiopathic paroxysmal atrial fibrillation;
D O I
10.1111/j.1540-8159.2000.tb00913.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We hypothesized that the variance of P wave duration (P variance) in the 12-lead ECG could reflect the spatial dispersion of P wave duration due to inhomogeneous and delayed propagation of sinus impulses in the atria, and moreover could present better reproducibility than maximum P wave duration and P wave dispersion that have already been used for the prediction of idiopathic paroxysmal AF. We also tested a semiautomated PC-based method to improve the accuracy and reproducibility of P wave measurements. A 12-lead ECG was obtained from 60 patients with idiopathic paroxysmal AF and from 50 healthy controls. All ECGs were analyzed manually using magnifying lens and calipers, while 20 randomly selected ones were scanned and analyzed on screen using common commercial software. P maximum, P dispersion, and P variance were all significantly higher in patients with paroxysmal AF than in controls. A P maximum value of 110 ms, a P dispersion value of 40 ms, and a P variance value of 120 ms(2) separated patients from controls with a sensitivity of 88%, 83%, and 80%, respectively and a specificity of 75%, 85%, and 74%, respectively. The reproducibility of P variance was higher compared to P dispersion and P maximum. Finally, the PC-based method significantly increased accuracy and reproducibility of P wave measurements. Thus, the variance of P wave duration could be a useful ECG marker for the prediction of paroxysmal idiopathic AF and the use of PC-based methods may enhance the accurate measuring of P wave duration on the ECG.
引用
收藏
页码:1127 / 1132
页数:6
相关论文
共 29 条
[1]  
Andrikopoulos G., 1998, European Heart Journal, V19, P665
[2]  
Andrikopoulos George K., 1999, Journal of the American College of Cardiology, V33, p143A
[3]  
[Anonymous], 1985, Cardiac arrhythmias
[4]   THE ROLE OF P-WAVE DURATION AS A PREDICTOR OF POSTOPERATIVE ATRIAL ARRHYTHMIAS [J].
BUXTON, AE ;
JOSEPHSON, ME .
CHEST, 1981, 80 (01) :68-73
[5]   ELECTROCARDIOGRAPHIC EVIDENCE OF LEFT ATRIAL HYPERTENSION IN ACUTE MYOCARDIAL-INFARCTION [J].
CHANDRARATNA, PA ;
HODGES, M .
CIRCULATION, 1973, 47 (03) :493-498
[6]   The role of P wave in prediction of atrial fibrillation after coronary artery surgery [J].
Chang, CM ;
Lee, SH ;
Lu, MJ ;
Lin, CH ;
Chao, HH ;
Cheng, JJ ;
Kuan, P ;
Hung, CR .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 68 (03) :303-308
[7]  
DAVIES LG, 1963, BRIT HEART J, V25, P570
[8]  
DILAVERIS P, 1997, PACE 2, V20, P1098
[9]   Effects of ischemia on P wave dispersion and maximum P wave duration during spontaneous anginal episodes [J].
Dilaveris, PE ;
Andrikopoulos, GK ;
Metaxas, G ;
Richter, DJ ;
Avgeropoulou, CK ;
Androulakis, AM ;
Gialafos, EJ ;
Michaelides, AP ;
Toutouzas, PK ;
Gialafos, JE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (11) :1640-1647
[10]   Detection of hypertensive patients at risk for paroxysmal atrial fibrillation during sinus rhythm by computer-assisted P wave analysis [J].
Dilaveris, PE ;
Gialafos, EJ ;
Chrissos, D ;
Andrikopoulos, GK ;
Richter, DJ ;
Lazaki, E ;
Gialafos, JE .
JOURNAL OF HYPERTENSION, 1999, 17 (10) :1463-1470