Surface plasmon resonance/mass spectrometry interface

被引:38
作者
Grote, J
Dankbar, N
Gedig, E
Koenig, S
机构
[1] Univ Munster, Fac Med, Interdisciplinary Ctr Clin Res, D-48149 Munster, Germany
[2] XanTec Bioanalyt GmbH, Munster, Germany
关键词
D O I
10.1021/ac049033d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A strategy for combining surface plasmon resonance (SPR) biomolecular interaction analysis, and matrixassisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. Both techniques are highly complementary but need separate optimization to improve their individual specificity and sensitivity. Sensor surfaces that are optimal for kinetic analysis are not well suited for MALDI-MS and vice versa. In addition, the transfer of analyte from SPR to MS is crucial and often accompanied by sample loss. To address both of these points, a bifunctional SPR fluid cell was constructed where optimized surfaces can be used for binding studies and MS simultaneously with regard to the special need of each technique. The setup guarantees that the SPR and the loading experiment for MS are performed at identical conditions. A removable pin carries the affinity-surface-bound analyte to the mass spectrometer so that handling is minimized, avoiding analyte elution. Functionalized transfer pins can also be used independently of SPR for microaffinity capture-MS.
引用
收藏
页码:1157 / 1162
页数:6
相关论文
共 38 条
[1]   A post-genomic challenge: learning to read patterns of protein synthesis [J].
Abbott, A .
NATURE, 1999, 402 (6763) :715-720
[2]  
BARTEL PL, 1995, METHOD ENZYMOL, V254, P241
[3]  
BERGSTROM J, 1990, Patent No. 9005303
[4]   Kinetic analysis of the mass transport limited interaction between the tyrosine kinase Ick SH2 domain and a phosphorylated peptide studied by a new cuvette-based surface plasmon resonance instrument [J].
de Mol, NJ ;
Plomp, E ;
Fischer, MJE ;
Ruijtenbeek, R .
ANALYTICAL BIOCHEMISTRY, 2000, 279 (01) :61-70
[5]   The effect of a receptor layer on the measurement of rate constants [J].
Edwards, DA .
BULLETIN OF MATHEMATICAL BIOLOGY, 2001, 63 (02) :301-327
[6]   Effect of hydrogel matrix on binding kinetics of protein-protein interactions on sensor surface [J].
Fong, CC ;
Wong, MS ;
Fong, WF ;
Yang, MS .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :201-208
[7]   THE USE OF AFFINITY-CHROMATOGRAPHY TO STUDY PROTEINS INVOLVED IN BACTERIOPHAGE-T4 GENETIC-RECOMBINATION [J].
FORMOSA, T ;
ALBERTS, BM .
COLD SPRING HARBOR SYMPOSIA ON QUANTITATIVE BIOLOGY, 1984, 49 :363-370
[8]  
GEDIG E, 2003, ANAL GENE EXPRESSION, V2, P660
[9]   Mass spectrometry after capture and small-volume elution of analyte from a surface plasmon resonance biosensor [J].
Gilligan, JJ ;
Schuck, P ;
Yergey, AL .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2041-2047
[10]  
GROTE J, 2004, LAB WORKSHOP MOL MOD