Ultrathin poly(ethylene glycol) films for silicon-based microdevices

被引:59
作者
Sharma, S
Johnson, RW
Desai, TA [1 ]
机构
[1] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[2] Abbott Labs, Struct Chem, Abbott Pk, IL 60064 USA
[3] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
基金
美国国家科学基金会;
关键词
poly(ethylene glycol); silicon; microdevices; thin films; covalent coupling;
D O I
10.1016/S0169-4332(02)01220-5
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Development of poly(ethylene glycol) (PEG) films that are ultrathin, uniform, conformal and stable in vivo-like environments is extremely desirable for biocompatible silicon-based microdevices. To this end, we have characterized PEG thin films, created by chemical coupling, at different PEG concentrations for various immobilization times, using the techniques of X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), ellipsometry and contact angle measurement. A continuous increase in film thickness and contact angle was measured with increase in PEG concentration and immobilization time (30-120 min). The surface roughness had a minimum value for 1.0% PEG (immobilization time = 60 min). The biocompatibility of ultrathin PEG films was also tested using fluorescein isothiocyanate (FITC)-labeled bovine serum albumin (BSA). Results indicated PEG-modified silicon surfaces to be more resistant to protein adsorption. The stability of ultrathin PEG films over time in dry and aqueous in vivo-like environments was also examined. While ultrathin PEG films were extremely stable in dry conditions, their stability was compromised in aqueous in vivo-like environments (PBS, 37 degreesC, pH 7.4, 5% CO2). Nevertheless, ultrathin PEG films retained their efficacy to control protein fouling for the period investigated. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:218 / 229
页数:12
相关论文
共 38 条
[1]  
Alcantar NA, 2000, J BIOMED MATER RES, V51, P343, DOI 10.1002/1097-4636(20000905)51:3<343::AID-JBM7>3.0.CO
[2]  
2-D
[3]   SURFACE MODIFICATION BY RADIATION-INDUCED GRAFTING OF PEO/PPO/PEO TRIBLOCK COPOLYMERS [J].
AMIJI, M ;
PARK, K .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1993, 155 (01) :251-255
[4]   PREVENTION OF PROTEIN ADSORPTION AND PLATELET-ADHESION ON SURFACES BY PEO PPO PEO TRIBLOCK COPOLYMERS [J].
AMIJI, M ;
PARK, K .
BIOMATERIALS, 1992, 13 (10) :682-692
[5]  
AMIJI M, 1991, T SOC BIOMATER, V14, P41
[6]   Long-term stability of grafted polyethylene glycol surfaces for use with microstamped substrates in neuronal cell culture [J].
Branch, DW ;
Wheeler, BC ;
Brewer, GJ ;
Leckband, DE .
BIOMATERIALS, 2001, 22 (10) :1035-1047
[7]   The subretinal microphotodiode array retinal prosthesis II [J].
Chow, AY ;
Peachey, N .
OPHTHALMIC RESEARCH, 1999, 31 (03) :246-246
[8]  
CUYPERS PA, 1983, J BIOL CHEM, V258, P2426
[9]  
Desai TA, 1998, BIOTECHNOL BIOENG, V57, P118, DOI 10.1002/(SICI)1097-0290(19980105)57:1<118::AID-BIT14>3.0.CO
[10]  
2-G