Frameless localization for functional neurosurgical procedures: A preliminary accuracy study

被引:28
作者
Henderson, JM [1 ]
机构
[1] St Louis Univ, St Louis, MO 63103 USA
关键词
image-guided surgery; functional neurosurgery; pallidotomy; deep brain stimulation;
D O I
10.1159/000081345
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Targeting for functional stereotactic procedures is traditionally carried out in a noninteractive fashion, without real-time positional feedback. In addition, stereotactic frames are uncomfortable for patients and may impede intraoperative neurological evaluation. As an initial step toward a fully frameless approach to functional surgery, we have investigated the use of an image-guided microdrive coupled to a stereotactic frame system. Methods: For initial laboratory tests, a stereotactic phantom was imaged using high-resolution CT scanning. Three representative targets were chosen within the phantom. Targeting was carried out in the usual fashion using the StealthStation planning suite, utilizing the Radionics CRW system. An LED-equipped reference arc was attached to the CRW base ring. Registration of the base ring was accomplished using a spherical probe. A custom-built microdrive was fitted with an LED array, mounted on the CRW arc and tracked by the StealthStation. The distance between the Stealth real-time localization and the CRW localization was measured on-screen. To evaluate the accuracy of the system in the operating room, a similar procedure was carried out in 13 functional neurosurgical operations (pallidotomy or deep brain stimulator placement). Results: Errors of localization in the laboratory setting ranged from 0.53 to 0.70 mm. In 11 operative cases, the average difference between the CRW localization and the Stealth localization was 1.77 mm. In the remaining 2 cases, equipment malfunction prevented measurement of localization error. Conclusions: Frameless image-guided localization compares favorably to targeting performed noninteractively. In addition, real-time positional feedback confers advantages in target region visualization and confidence in placement of lesions and stimulators for functional procedures. With small improvements in accuracy and system reliability, fully frameless functional procedures could be safely carried out. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 17 条
[1]   Comparison of frameless stereotactic systems: Accuracy, precision, and applications [J].
Benardete, EA ;
Leonard, MA ;
Weiner, HL .
NEUROSURGERY, 2001, 49 (06) :1409-1415
[2]  
CARROLL CJ, 2002, Patent No. 6482182
[3]   Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies - Technical note [J].
Dorward, NL ;
Alberti, O ;
Palmer, JD ;
Kitchen, ND ;
Thomas, DGT .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :160-168
[4]   Clinical use of the optical digitizer for intracranial neuronavigation [J].
Germane, IM ;
Villalobos, H ;
Silvers, A ;
Post, KD .
NEUROSURGERY, 1999, 45 (02) :261-269
[5]  
Germano I M, 1998, Comput Aided Surg, V3, P33, DOI 10.3109/10929089809148126
[6]   CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES [J].
GOLFINOS, JG ;
FITZPATRICK, BC ;
SMITH, LR ;
SPETZLER, RF .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :197-205
[7]  
Helm P A, 1998, Comput Aided Surg, V3, P51, DOI 10.1002/(SICI)1097-0150(1998)3:2<51::AID-IGS1>3.0.CO
[8]  
2-J
[9]  
HENDERSON JM, 2001, SEMIN NEUROSURG, V12, P175
[10]  
Kitchen Neil D., 1993, Stereotactic and Functional Neurosurgery, V61, P195, DOI 10.1159/000100637