Relationship between outdoor and indoor air quality in eight French schools

被引:254
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 28 条
[1]   INDOOR-OUTDOOR RELATIONSHIPS FOR AIRBORNE PARTICULATE MATTER OF OUTDOOR ORIGIN [J].
ALZONA, J ;
COHEN, BL ;
RUDOLPH, H ;
JOW, HN ;
FROHLIGER, JO .
ATMOSPHERIC ENVIRONMENT, 1979, 13 (01) :55-60
[2]  
Annesi-Maesano I., 2002, ETUDE IMPACT POLLUTI
[3]   Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships [J].
Baek, SO ;
Kim, YS ;
Perry, R .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) :529-544
[4]  
BLONDEAU P, 2002, ETUDE IMPACT POLLUTI, V155
[5]   REMOVAL OF REACTIVE GASES AT INDOOR SURFACES - COMBINING MASS-TRANSPORT AND SURFACE KINETICS [J].
CANORUIZ, JA ;
KONG, D ;
BALAS, RB ;
NAZAROFF, WW .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (13) :2039-2050
[6]   Comparison between indoor and outdoor air contaminant levels in residential buildings from passive sampler study [J].
Chao, CYH .
BUILDING AND ENVIRONMENT, 2001, 36 (09) :999-1007
[7]   Dry deposition of ozone on building materials. Chamber measurements and modelling of the time-dependent deposition [J].
Grontoft, T .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (36-37) :5661-5670
[8]   ACTIVITY PATTERNS OF CALIFORNIANS - USE OF AND PROXIMITY TO INDOOR POLLUTANT SOURCES [J].
JENKINS, PL ;
PHILLIPS, TJ ;
MULBERG, EJ ;
HUI, SP .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (12) :2141-2148
[9]  
KIRCHNER S, 2001, ETUDE EXPT CONDITION
[10]   The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants [J].
Klepeis, NE ;
Nelson, WC ;
Ott, WR ;
Robinson, JP ;
Tsang, AM ;
Switzer, P ;
Behar, JV ;
Hern, SC ;
Engelmann, WH .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (03) :231-252