Geometric misalignment and calibration in cone-beam tomography

被引:122
作者
von Smekal, L [1 ]
Kachelriess, M [1 ]
Stepina, E [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, IMP, D-91052 Erlangen, Germany
关键词
cone-beam computed tomography; CT; micro-CT; geometric calibration; misalignment;
D O I
10.1118/1.1803792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a new high-precision method for the geometric calibration in cone-beam computed tomography. It is based on a Fourier analysis of the projection-orbit data, recorded with a flat-panel area detector, of individual point-like objects. For circular scan trajectories the complete set of misalignment parameters which determine the deviation of the detector alignment from the ideal scan geometry are obtained from explicit analytic expressions. To derive these expressions we show how to disentangle the problems of calculating misalignment parameters and point coordinates. The calculation of the coordinates of the point objects inside the scanned volume, in units of the distance from the focal spot to the center of rotation, is then possible analytically likewise. We simulate point-projection data on a misaligned detector with various amounts of randomness added to mimic measurement uncertainties. This data is then employed in our calibration to validate the method by comparing the resulting misalignment parameters and point coordinates to the known true ones. We also present our implementation and results for the geometric calibration of micro-CT systems. The effectiveness of the corresponding misalignment correction in reducing image artifacts is exemplified by reconstructed micro-CT images. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3242 / 3266
页数:25
相关论文
共 16 条
[1]   CALCULATION OF THE ROTATIONAL CENTERS IN COMPUTED-TOMOGRAPHY SINOGRAMS [J].
AZEVEDO, SG ;
SCHNEBERK, DJ ;
FITCH, JP ;
MARTZ, HE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (04) :1525-1540
[2]   Characterization of pinhole SPECT acquisition geometry [J].
Bequé, D ;
Nuyts, J ;
Bormans, G ;
Suetens, P ;
Dupont, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) :599-612
[3]   Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements [J].
Bronnikov, AV .
OPTICAL ENGINEERING, 1999, 38 (02) :381-386
[4]   RECONSTRUCTION FOR FAN BEAM WITH AN ANGULAR-DEPENDENT DISPLACED CENTER-OF-ROTATION [J].
CRAWFORD, CR ;
GULLBERG, GT ;
TSUI, BMW .
MEDICAL PHYSICS, 1988, 15 (01) :67-71
[5]   ESTIMATION OF GEOMETRICAL PARAMETERS FOR FAN BEAM TOMOGRAPHY [J].
GULLBERG, GT ;
TSUI, BMW ;
CRAWFORD, CR ;
EDGERTON, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (12) :1581-1594
[6]   ESTIMATION OF GEOMETRICAL PARAMETERS AND COLLIMATOR EVALUATION FOR CONE BEAM TOMOGRAPHY [J].
GULLBERG, GT ;
TSUI, BMW ;
CRAWFORD, CR ;
BALLARD, JG ;
HAGIUS, JT .
MEDICAL PHYSICS, 1990, 17 (02) :264-272
[7]   Three-dimensional artifact induced by projection weighting and misalignment [J].
Hsieh, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (04) :364-368
[8]   Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates [J].
Karolczak, M ;
Schaller, S ;
Engelke, K ;
Lutz, A ;
Taubenreuther, U ;
Wiesent, K ;
Kalender, W .
MEDICAL PHYSICS, 2001, 28 (10) :2050-2069
[9]   Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography [J].
Noo, F ;
Clackdoyle, R ;
Mennessier, C ;
White, TA ;
Roney, TJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3489-3508
[10]  
Press W. H., 1992, SMR, V2nd