Determination of cadmium, lead and thallium in highly saline hemodialysis solutions by potentiometric stripping analysis (PSA)

被引:23
作者
do Nascimento, PC [1 ]
Bohrer, D [1 ]
de Carvalho, LM [1 ]
Caon, CE [1 ]
Pilau, E [1 ]
Vendrame, ZB [1 ]
Stefanello, R [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97111970 Santa Maria, RS, Brazil
关键词
potentiometric stripping analysis; Mercury film electrode; Hg(II) oxidant solution;
D O I
10.1016/j.talanta.2004.08.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric stripping analysis (PSA) was investigated to assay simultaneously cadmium, lead and thallium present as contaminants in highly saline solutions used in hemodialysis. The saline matrices were sodium, potassium, magnesium and calcium chlorides, sodium acetate, odium bicarbonate and glucose, which constitute concentrates for hemodialysis. A 1000 VLa mL -(It) solution was used to prepare the mercury film electrode (MFE) and to carry out the stripping step. After a 30 s accumulation interval the analytes were simultaneously detected in the saline matrices without using masking agents. Determination limits of 80 ng L-1 for cadmium and thallium, and 50 ng L-1 for lead were calculated and a R.S.D. ranging from 0.5 to 2.2% (n = 3) was obtained measuring the analytes directly in commercial hemodialysis saline solutions. Recoveries from spiked samples ranging from 94.6 to 102.0% were obtained. The investigated metals were found in concentrations ranging from 2.7 to 5.7 mug L-1 for cadmium, 27.7 to 75.8 mu L-1 for lead and 9.6 to 18.7 mug L-1 for thallium in commercial hemodialysis,solution,,. The PSA method showed to be adequate to the quality control of saline concentrates for hemodialysis. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:954 / 959
页数:6
相关论文
共 36 条
[1]  
*ACS COMM ENV IMPR, 1983, PINCIPLES ENF ANAL C, V55, P2210
[2]   ALUMINUM INTOXICATION [J].
ALFREY, AC .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (17) :1113-1115
[3]  
*ASS ADV MED INSTR, 1993, RD51992 ANSI AAMI
[4]  
Bohrer D, 1998, FRESEN J ANAL CHEM, V362, P224
[5]   Electrothermal atomic absorption spectrometric determination of lead, cadmium, copper and zinc in high-salt content samples after simultaneous separation on polyethylene powder impregnated with 1-(2-pyridylazo)-2-naphthol: application to the analysis of hemodialysis fluids [J].
Bohrer, D ;
do Nascimento, PC ;
Guterres, M ;
Trevisan, M ;
Seibert, E .
ANALYST, 1999, 124 (09) :1345-1350
[6]   Characteristics of subtractive anodic stripping voltammetry of lead, cadmium and thallium at silver-gold alloy electrodes [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ELECTROANALYSIS, 2003, 15 (17) :1369-1376
[7]   Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode [J].
Bonfil, Y ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :285-296
[8]   Human exposure to metals.: Pathways of exposure, biomarkers of effect, and host factors [J].
Calderón, J ;
Ortiz-Pérez, D ;
Yáñez, L ;
Díaz-Barriga, F .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2003, 56 (01) :93-103
[9]   An innovative extracorporeal membrane system for enzyme-mediated blood purification [J].
Cioci, F ;
Lavecchia, R .
CHEMICAL ENGINEERING SCIENCE, 1996, 51 (11) :2823-2828
[10]  
DHaese PC, 1996, NEPHROL DIAL TRANSPL, V11, P92