The assessment of circulating 25(OH)D and 1,25(OH)2D:: Where we are and where we are going

被引:96
作者
Hollis, Bruce W.
Horst, Ronald L.
机构
[1] Med Univ S Carolina, Dept Pediat, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Biochem & Mol Biol, Charleston, SC 29425 USA
[3] Natl Anim Dis Ctr, Ames, IA 50010 USA
关键词
vitamin D assay; 25-hvdroxyvitamin D; 1,25-dihydroxyvitamin D;
D O I
10.1016/j.jsbmb.2006.11.004
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The field of Vitamin D assay technology has progressed significantly over the past 4 decades. Further, the clinical utility of these measurements has moved from esoteric into mainstream clinical diagnosis. This movement has been fueled by the realization that Vitamin D is involved in bodily systems beyond skeletal integrity. The clinical assay techniques for circulating 25(OH)D and 1,25(OH)(2)D have progressed away from competitive protein binding assay (CPBAs) that utilize tritium reporters to radioimmunoassay (RIAs) that utilize both I-125 and chemiluminescent reporters. These advances have allowed direct serum analysis of 25(OH)D in an automated format that provides a huge sample throughput. Detection of circulating 25(OH)D can also be achieved utilizing direct high-performance liquid chromatographic (HPLC) or liquid chromatography coupled with mass spectrometry (LC-MS) techniques. These methods are accurate, however, they require expensive equipment and restrict sample throughput in the large clinical laboratory. Direct serum detection of 1,25(OH)(2)D is unlikely to occur for many reasons as a sample pre-purification will always be required. However, a semi-automated chemiluminescent detection system with automated sample preparation is in final development for the determination of circulating 1,25(OH)(2)D. These advances will allow both 25(OH)D and 1,25(OH)(2)D to be detected in an accurate, rapid fashion to meet the clinical demands we see emerging. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:473 / 476
页数:4
相关论文
共 27 条
[1]   RAPID ASSAY FOR 25-HYDROXY-VITAMIN-D3 WITHOUT PREPARATIVE CHROMATOGRAPHY [J].
BELSEY, RE ;
DELUCA, HF ;
POTTS, JT .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1974, 38 (06) :1046-1051
[2]   Assay variation confounds the diagnosis of hypovitaminosis D: A call for standardization [J].
Binkley, N ;
Krueger, D ;
Cowgill, CS ;
Plum, L ;
Lake, E ;
Hansen, KE ;
DeLuca, HF ;
Drezner, MK .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (07) :3152-3157
[3]   RADIORECEPTOR ASSAY FOR 1ALPHA, 1,ALPHA,25-DIHYDROXYVITAMIN-D3 D3 [J].
BRUMBAUGH, PF ;
HAUSSLER, DH ;
BRESSLER, R ;
HAUSSLER, MR .
SCIENCE, 1974, 183 (4129) :1089-1091
[4]   How accurate are assays for 25-hydroxyvitamin D? Data from the international vitamin D external quality assessment scheme [J].
Carter, GD ;
Carter, R ;
Jones, J ;
Berry, J .
CLINICAL CHEMISTRY, 2004, 50 (11) :2195-2197
[5]   Genetic evidence that the human CYP2R1 enzyme is a key vitamin D 25-hydroxylase [J].
Cheng, JB ;
Levine, MA ;
Bell, NH ;
Mangelsdorf, DJ ;
Russell, DW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (20) :7711-7715
[6]   RADIOIMMUNOASSAY FOR 1,25-DIHYDROXYCHOLECALCIFEROL [J].
CLEMENS, TL ;
HENDY, GN ;
GRAHAM, RF ;
BAGGIOLINI, EG ;
USKOKOVIC, MR ;
ORIORDAN, JLH .
CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1978, 54 (03) :329-332
[7]  
DABEK JT, 1981, CLIN CHEM, V27, P1346
[8]   1,25-DIHYDROXYVITAMIN-D IN BIOLOGICAL-FLUIDS - SIMPLIFIED AND SENSITIVE ASSAY [J].
EISMAN, JA ;
HAMSTRA, AJ ;
KREAM, BE ;
DELUCA, HF .
SCIENCE, 1976, 193 (4257) :1021-1023
[9]   SENSITIVE, PRECISE, AND CONVENIENT METHOD FOR DETERMINATION OF 1,25-DIHYDROXYVITAMIN-D IN HUMAN-PLASMA [J].
EISMAN, JA ;
HAMSTRA, AJ ;
KREAM, BE ;
DELUCA, HF .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1976, 176 (01) :235-243
[10]   DETERMINATION OF 25-HYDROXYVITAMIN D2 AND 25-HYDROXYVITAMIN D3 IN HUMAN-PLASMA USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
EISMAN, JA ;
SHEPARD, RM ;
DELUCA, HF .
ANALYTICAL BIOCHEMISTRY, 1977, 80 (01) :298-305