Use of dyes as indirect detection probes for the high-sensitivity determination of anions by capillary electrophoresis

被引:45
作者
Doble, P [1 ]
Macka, M [1 ]
Haddad, PR [1 ]
机构
[1] Univ Tasmania, Dept Chem, Hobart, Tas 7001, Australia
关键词
buffer compositions; dyes; bromocresol green; indigo-tetrasulfonate; alkanesulfonic acids; inorganic anions; organic acids;
D O I
10.1016/S0021-9673(98)00025-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High sensitivity for indirect detection was achieved by utilising highly absorbing species as the displaced co-ion (or probe). Two highly absorbing dyes, bromocresol green and indigo-tetrasulfonate, were investigated as potential probes in the determination of small organic and inorganic anions. The concentration of these probes was kept as low as possible to ensure the signal-to-noise ratios were reasonable and the background absorbance was within the linear range of the detector. Four different protocols for buffering the electrolyte with such low probe concentrations were investigated. Buffering with agents that introduce co-anions [acetate or 2-(cyclohexylamino)ethanesulfonic acid (CHES) buffers] proved unsuitable as detection sensitivities were diminished due to competitive displacement by the analytes and system peaks were also induced. Buffering without introduction of co-anions was achieved using the buffering base, diethanolamine, or the use of ampholytes, lysine and glutamic acid. For separations performed with these two buffering approaches, migration time reproducibilities were less than 1% R.S.D. for most analytes. Minimal detectable amounts were in the low attomol region (1.10(-18) mel), corresponding to sub-mu M vacuum injected solution concentrations. These were an order of magnitude lower than the general detection limit reported for indirect photometric detection, and were comparable with detection limits achieved with indirect fluorescence detection. Finally, the detection limits were further improved by approximately three times for anions analyser with indigo-tetrasulfonate as the probe when a Z cell was employed as the detection cell. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 23 条
[1]   QUANTITATIVE-ANALYSIS IN CAPILLARY ZONE ELECTROPHORESIS WITH CONDUCTIVITY AND INDIRECT UV DETECTION [J].
ACKERMANS, MT ;
EVERAERTS, FM ;
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :345-355
[2]   SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS [J].
ALBIN, M ;
GROSSMAN, PD ;
MORING, SE .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :A489-A497
[3]   UV DETECTION IN CAPILLARY ZONE ELECTROPHORESIS PEAKS OR DIPS - THAT IS THE QUESTION [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY A, 1994, 679 (01) :153-165
[4]   THEORETICAL AND EXPERIMENTAL ASPECTS OF INDIRECT DETECTION IN CAPILLARY ELECTROPHORESIS [J].
BRUIN, GJM ;
VANASTEN, AC ;
XU, XM ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :97-107
[5]   Z-SHAPED FLOW CELL FOR UV-DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHERVET, JP ;
VANSOEST, REJ ;
URSEM, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02) :439-449
[6]   Buffered chromate electrolytes for separation and indirect absorbance detection of inorganic anions in capillary electrophoresis [J].
Doble, P ;
Macka, M ;
Andersson, P ;
Haddad, PR .
ANALYTICAL COMMUNICATIONS, 1997, 34 (11) :351-353
[7]   Determination and prediction of transfer ratios for anions in capillary zone electrophoresis with indirect UV detection [J].
Doble, P ;
Andersson, P ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 1997, 770 (1-2) :291-300
[8]  
DOBLE PA, UNPUB
[9]   INDIRECT PHOTOMETRIC DETECTION IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
FANALI, S ;
OSSICINI, L ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1989, 470 (01) :299-308
[10]   FAST, HIGH-RESOLUTION (CAPILLARY) ELECTROPHORESIS IN BUFFERS DESIGNED FOR HIGH-FIELD STRENGTHS [J].
HJERTEN, S ;
VALTCHEVA, L ;
ELENBRING, K ;
LIAO, JL .
ELECTROPHORESIS, 1995, 16 (04) :584-594