Intraoperative imaging techniques to assess coronary artery bypass graft patency

被引:95
作者
Balacumaraswami, Lognathen [1 ]
Taggart, David P. [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Dept Cardiothorac Surg, Oxford OX3 9DU, England
关键词
D O I
10.1016/j.athoracsur.2006.12.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Graft patency verification is increasingly recognized as an important component of coronary artery bypass grafting. Intuitively, eliminating intraoperative graft failure should reduce cardiac mortality and morbidity in the short term and improve clinical outcome in the long term. Although conventional angiography remains the gold standard technique for assessing graft patency, it is rarely available in the operating room and consequently several other less invasive approaches have been advocated. This article reviews the two currently most commonly used modalities for graft patency assessment, intraoperative fluorescence imaging and transit-time flowmetry, and discusses their value and limitations. Both techniques can reliably detect otherwise unsuspected occluded grafts and this is crucial for internal thoracic arteries because of their prognostic significance. Although neither technology can consistently identify more minor, non-occlusive abnormalities, the intraoperative fluorescence imaging technique seems to be more sensitive and less susceptible to "false positive" images.
引用
收藏
页码:2251 / 2257
页数:7
相关论文
共 41 条
[1]   Off-pump coronary artery bypass grafting [J].
Abu-Omar, Y ;
Taggart, DP .
LANCET, 2002, 360 (9329) :327-329
[2]  
Alexander JH, 2005, JAMA-J AM MED ASSOC, V294, P2446
[3]   Does off-pump total arterial grafting increase the incidence of intraoperative graft failure? [J].
Balacumaraswami, L ;
Abu-Omar, Y ;
Anastasiadis, K ;
Choudhary, B ;
Pigott, D ;
Yeong, SK ;
Taggart, DP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (02) :238-244
[4]   A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency [J].
Balacumaraswami, L ;
Abu-Omar, Y ;
Choudhary, B ;
Pigott, D ;
Taggart, DP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02) :315-320
[5]  
Balacumaraswami Lognathen, 2004, Semin Thorac Cardiovasc Surg, V16, P266, DOI 10.1053/j.semtcvs.2004.08.014
[6]   ULTRASONIC ASSESSMENT OF INTERNAL THORACIC ARTERY GRAFT FLOW IN THE REVASCULARIZED HEART [J].
CANVER, CC ;
DAME, NA .
ANNALS OF THORACIC SURGERY, 1994, 58 (01) :135-138
[7]  
Canver CC, 1997, J CARDIOVASC SURG, V38, P211
[8]   Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting [J].
D'Ancona, G ;
Karamanoukian, HL ;
Ricci, M ;
Schmid, S ;
Bergsland, J ;
Salerno, TA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) :287-293
[9]  
DANCONA G, 2001, INTRAOPERATIVE GRAFT
[10]   Improving the quality of coronary bypass surgery with intraoperative angiography - Validation of a new technique [J].
Desai, ND ;
Miwa, S ;
Kodama, D ;
Cohen, G ;
Christakis, GT ;
Goldman, BS ;
Baerlocher, MO ;
Pelletier, MP ;
Fremes, SE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) :1521-1525