Methodological concerns for determining power output in the jump squat

被引:9
作者
Cormie, Prue
Deane, Russell
McBride, Jeffrey M. [1 ]
机构
[1] Appalachian State Univ, Dept Hlth Leisure & Exercise Sci, Neuromuscular Lab, Boone, NC 28607 USA
[2] Edith Cowan Univ, Sch Exercise Biomed & Hlth Sci, Perth, WA, Australia
关键词
force; velocity; countermovement jump;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 [教育学]; 0403 [体育学];
摘要
Cormie, P., R. Deane, and J.M. McBride. Methodological concerns for determining power output in the jump squat. J. Strength Cond. Res. 21(2):424-430. 2007. - The purpose of this study was to investigate the validity of power measurement techniques during the jump squat (JS) utilizing various combinations of a force plate and linear position transducer (LPT) devices. Nine men with at least 6 months of prior resistance training experience participated in this acute investigation. One repetition maximums (1RM) in the squat were determined, followed by JS testing under 2 loading conditions (30% of 1RM [JS30] and 90% of 1RM [JS90]). Three different techniques were used simultaneously in data collection: (a) 1 linear position transducer (1-LPT); (b) 1 linear position transducer and a force plate (1-LPT + FP); and (c) 2 linear position transducers and a force place (2-LPT + FP). Vertical velocity-, force-, and power-time curves were calculated for each lift using these methodologies and were compared. Peak force and peak power were overestimated by 1-LPT in both JS30 and JS90 compared with 2-LPT + FP and 1-LPT + FP (p <= 0.05). Peak power determined by 2-LPT + FP was significantly higher than that determined by 1-LPT + FP under the JS90 loading condition. Peak vertical velocity determined by 2-LPT + FP was significantly lower than that determined by either 1-LPT and 1-LPT + FP in JS90. This investigation indicates that peak power and the timing of power output in the jump squat varies according to the measurement technique utilized. The 1-LPT methodology is not a valid means of determining power output in the jump squat. Furthermore, the 1-LPT + FP method may not accurately represent power output in free weight movements that involve a significant amount of horizontal motion.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 26 条
[1]
Alemany JA, 2005, J STRENGTH COND RES, V19, P33
[2]
Baker D, 1999, J STRENGTH COND RES, V13, P230
[3]
Baker D, 2001, J STRENGTH COND RES, V15, P20
[4]
BOURQUE S, 2003, THESIS U NEW BRUNSWI
[5]
Measurement of resistance exercise force expression [J].
Chiu, LZF ;
Schilling, BK ;
Fry, AC ;
Weiss, LW .
JOURNAL OF APPLIED BIOMECHANICS, 2004, 20 (02) :204-212
[6]
Reliability and validity of a linear position transducer for measuring jump performance [J].
Cronin, JB ;
Hing, RD ;
McNair, PJ .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2004, 18 (03) :590-593
[7]
Cronin JB, 2004, J STRENGTH COND RES, V18, P48
[8]
Determining the optimal load for jump squats: A review of methods and calculations [J].
Dugan, EL ;
Doyle, TLA ;
Humphries, B ;
Hasson, CJ ;
Newton, RU .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2004, 18 (03) :668-674
[9]
The acute effects of heavy loads on jump squat performance: An evaluation of the complex and contrast methods of power development [J].
Duthie, GM ;
Young, WB ;
Aitken, DA .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2002, 16 (04) :530-538
[10]
ELSLIGER DW, 2003, THESIS NEW BRUNSWICK