Step ahead adaptive control technique for wind systems

被引:12
作者
Dadone, A [1 ]
Dambrosio, L [1 ]
Fortunato, B [1 ]
机构
[1] Politecn Bari, Ist Macchine & Energet, Bari, Italy
关键词
wind system; control; adaptive; one step ahead;
D O I
10.1016/S0196-8904(97)00019-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
The control of a wind system considered as an isolated source of power and composed of a horizontal-axis wind-turbine connected to an induction generator is analyzed. Appropriate mathematical models for both the horizontal-axis wind-turbine and the induction generator are-used. The one-step-ahead adaptive control technique is presented and used to regulate the wind system. A sensitivity analysis of the induction generator performances with respect to control and disturbance variables is presented in order to evaluate the control flexibility. The results of three control problems are finally shown in order to prove the reliability of the suggested control technique. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:399 / 413
页数:15
相关论文
共 13 条
[1]  
[Anonymous], 1974, APPL AERODYNAMICS WI
[2]  
BROWN CJ, 1991, WIND ENERGY CONVERSION 1991, P255
[3]  
Bryson A. E., 1975, APPL OPTIMAL CONTROL
[4]  
CHVIAROPOULOS P, 1988, P EUR COMM WIND EN C, P258
[5]  
DAMBROSIO L, 1994, THESIS I MACCHINE EN
[6]  
DAMBROSIO L, 1994, THESIS MISSISSIPPI S
[7]  
FITZGERALD A.E., 1983, ELECT MACHINERY
[8]  
Fortunato B, 1994, P FLOW WORLD EN RES, P867
[9]  
Goodwin G C., 1984, ADAPTIVE FILTERING P
[10]  
MADSEN PH, 1988, EUR WIND ASS C HERN