Performance of new prototype packed columns for very high pressure liquid chromatography

被引:53
作者
Gritti, Fabrice [1 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
基金
美国国家科学基金会;
关键词
Very high pressure liquid chromatography; Heat effects; Temperature gradients; BEH-C-18; columns; Column efficiency; Naphtho[2,3-a]pyrene; Acetonitrile mobile phase; TEMPERATURE PROFILES; HPLC COLUMNS; EFFICIENCY; PARTICLES; DISSIPATION;
D O I
10.1016/j.chroma.2009.12.057
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
The reduced heights equivalent to a theoretical plate (HETP) of naphtho[2,3-a]pyrene were measured at room temperature on two sets of new prototype columns designed to be used in very high pressure liquid chromatography (VHPLC). The mobile phase used was pure acetonitrile. The columns are 50, 100, and 150 mm long. Those of the first set are 2.1 mm I.D., those of the second set, 3.0 mm I.D. The performance of these new Columns were compared to those of the first generation of VHPLC columns, commercially available in 2.1 mm I.D. The prototype and commercial columns behave similarly at low reduced linear velocities (v < 5), when the heat effects are negligible. At high flow rates, the shorter prototype columns have a twice better efficiency and less steep C-branches than the commercial columns. In contrast, the C-branch of the 150 mm long prototype columns are slightly steeper than those of the commercial columns. The important contribution to the reduced HETP that is due to the heat effects at high flow rates can in part be accounted for by a band broadening model governed by a flow mechanism with the shortest prototype columns. The sole heat effects cannot, however, explain the mediocre reduced HETPs of the 2.1 and 3.0 I.D. 150 mm long prototype columns. It seems that radial heterogeneity of the flow rate of the long prototype columns is significantly larger than that of the short columns. The contribution of the packing heterogeneity adds Lip to that of the heat effects to yield a poor column efficiency when sub-2 mu m are packed into thin, long column tubes. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1485 / 1495
页数:11
相关论文
共 30 条
[1]
Radial heterogeneity of some analytical columns used in high-performance liquid chromatography [J].
Abia, Jude A. ;
Mriziq, Khaled S. ;
Guiochon, Georges A. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) :3185-3191
[2]
[Anonymous], 2008, 32 INT S HIGH PERF L
[3]
ON THE DISPERSION OF A SOLUTE IN A FLUID FLOWING THROUGH A TUBE [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1200) :67-77
[4]
STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[5]
Chester TL, 2009, AM LAB, V41, P11
[6]
Contribution of the radial distribution of the flow velocity to band broadening in HPLC columns [J].
Farkas, T ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4592-4600
[7]
Giddings J.C., 1965, DYNAMICS CHROMATOGRA
[8]
GRITTI F, AICHE J IN PRESS
[9]
Fundamental chromatographic equations designed for columns packed with very fine particles and operated at very high pressures applications to the prediction of elution times and the column efficiencies [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1206 (02) :113-122
[10]
Heat exchanges in fast, high-performance liquid chromatography. A complete thermodynamic study [J].
Gritti, Fabrice ;
Guiochon, Georges .
ANALYTICAL CHEMISTRY, 2008, 80 (17) :6488-6499