Identification of an in vitro insulin receptor substrate-1 phosphorylation site by negative-ion μLC/ES-API-CID-MS hybrid scan technique

被引:23
作者
Beck, A
Moeschel, K
Deeg, M
Häring, HU
Voelter, W
Schleicher, ED
Lehmann, R
机构
[1] Univ Tubingen, Dept Internal Med 4, Div Clin Chem, Univ Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen, Inst Physiol Chem, D-72076 Tubingen, Germany
关键词
D O I
10.1016/S1044-0305(03)00122-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recently, we reported a fast on-line alkaline micro-liquid chromatography/electrosprayatmospheric pressure ionization/collision-induced dissociation/mass spectrometric approach for sensitive phosphopeptide screening of a tryptic digested protein and subsequent characterization of the identified phosphopeptide. Based on this study, we now applied an improved method for the identification of phosphorylation sites in insulin receptor substrate 1, an important mediator in insulin signal transduction which was phosphorylated in vitro by protein kinase C-zeta. The approach consists of an on-line alkaline negative-ion micro-liquid chromatography/electrospray-atmospheric pressure ionization/collision-induced dissociation/mass spectrometric hybrid scan experiment using a triple-quadrupole mass spectrometer with fractionation and subsequent off-line nanoES-MS (ion trap) analysis of the phosphopeptide-containing fractions. During the liquid chromatography (LC)/ES-MS experiment, the phosphopeptides of the enzymatic digest mixture of the studied insulin receptor substrate 1 fragment were detected under high skimmer potential (API-CID) using phosphorylation-specific m/z 79 marker ions as well as the intact m/z-values of the peptides which were recorded under low skimmer potential. Subsequently, the targeted fractions were analyzed by off-line nanoES-MS/MS and MS3. Using this approach, serine 318 was clearly identified as a major in vitro protein kinase C-zeta phosphorylation site in the insulin receptor substrate-1 fragment. Together, our results indicate that the applied strategy is useful for unequivocal and fast analysis of phosphorylation sites in low abundant signaling proteins.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 26 条
[1]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[2]   A multidimensional electrospray MS-based approach to phosphopeptide mapping [J].
Annan, RS ;
Huddleston, MJ ;
Verma, R ;
Deshaies, RJ ;
Carr, SA .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :393-404
[3]   Alkaline liquid chromatography/electrospray ionization skimmer collision-induced dissociation mass spectrometry for phosphopeptide screening [J].
Beck, A ;
Deeg, M ;
Moeschel, K ;
Schmidt, EK ;
Schleicher, ED ;
Voelter, WG ;
Häring, HU ;
Lehmann, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (23) :2324-2333
[4]   Selective detection and sequencing of phosphopeptides at the femtomole level by mass spectrometry [J].
Carr, SA ;
Huddleston, MJ ;
Annan, RS .
ANALYTICAL BIOCHEMISTRY, 1996, 239 (02) :180-192
[5]   Fragmentation of phosphopeptides in an ion trap mass spectrometer [J].
DeGnore, JP ;
Qin, J .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (11) :1175-1188
[6]   IDENTIFICATION OF PHOSPHORYLATED PEPTIDES FROM COMPLEX-MIXTURES USING NEGATIVE-ION ORIFICE-POTENTIAL STEPPING AND CAPILLARY LIQUID-CHROMATOGRAPHY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
DING, JM ;
BURKHART, W ;
KASSEL, DB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (01) :94-98
[7]   SELECTIVE DETECTION OF PHOSPHOPEPTIDES IN COMPLEX-MIXTURES BY ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HUDDLESTON, MJ ;
ANNAN, RS ;
BEAN, MF ;
CARR, SA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (09) :710-717
[8]   CHROMATOGRAPHIC AND MASS-SPECTROMETRIC METHODS FOR THE IDENTIFICATION OF PHOSPHORYLATION SITES IN PHOSPHOPROTEINS [J].
HUNTER, AP ;
GAMES, DE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) :559-570
[9]   Detection of modified peptides in enzymatic digests by capillary liquid chromatography electrospray mass spectrometry and a programmable skimmer CID acquisition routine [J].
Jedrzejewski, PT ;
Lehmann, WD .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :294-301
[10]  
Larsen MR, 2001, PROTEOMICS, V1, P223