摘要
Contamination of food by mycotoxins occurs in minute quantities, and therefore, there is a need for a highly sensitive and selective device that can detect and quantify these organic toxins. We report the development of a rapid and highly sensitive array biosensor for the detection and quantitation of ochratoxin A (OTA). The array biosensor utilizes a competitive immunoassay format. Immobilized OTA derivatives compete with toxin in solution for binding to fluorescent anti-OTA antibody spiked into the sample. This competition is quantified by measuring the formation of the fluorescent immunocomplex on the waveguide surface. The fluorescent signal is inversely proportional to the concentration of OTA in the sample. Analyses for OTA in buffer and a variety of food and beverage samples were performed. Samples were extracted with methanol, without any sample cleanup or preconcentration step prior to analysis. The limit of detection for OTA in several cereals ranged from 3.8 to 100 ng/g, while in coffee and wine, detection limits were 7 and 38 ng/g, respectively.
引用
收藏
页码:148 / 154
页数:7
相关论文
共 45 条
[1]  
[Anonymous], FEMS IMMUNOL MED MIC
[2]   Ochratoxin A determination in ham by immunoaffinity clean-up and a quick fluorometric method [J].
Chiavaro, E ;
Lepiani, A ;
Colla, F ;
Bettoni, P ;
Pari, E ;
Spotti, E .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (06) :575-581
[3]  
Chu FS, 1996, ACS SYM SER, V621, P294
[4]  
*COUNC AGR SCI TEC, 2003, 139 MYC RISKS PLANTS
[5]   Flow-through membrane-based enzyme immunoassay for rapid detection of ochratoxin A in wheat [J].
De Saeger, S ;
Van Peteghem, C .
JOURNAL OF FOOD PROTECTION, 1999, 62 (01) :65-69
[6]   Array Biosensor: Optical and Fluidics Systems [J].
Feldstein, Mark J. ;
Golden, Joel P. ;
Rowe, Chris A. ;
MacCraith, Brian D. ;
Ligler, Frances S. .
BIOMEDICAL MICRODEVICES, 1999, 1 (02) :139-153
[7]   A comparison of imaging methods for use in an array biosensor [J].
Golden, JP ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) :719-725
[8]  
GOLDEN JP, IN PRESS TALANTA
[9]   Automated microarray system for the simultaneous detection of antibiotics in milk [J].
Knecht, BG ;
Strasser, A ;
Dietrich, R ;
Märtlbauer, E ;
Niessner, R ;
Weller, MG .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :646-654
[10]   Ochratoxin A: Contamination of grain [J].
Kononenko, GP ;
Burkin, AA ;
Zotova, EV ;
Soboleva, NA .
APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2000, 36 (02) :177-180