Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental implants: A comparative in vitro study between machined and plasma-sprayed titanium surfaces

被引:23
作者
Chairay, JP
Boulekbache, H
Jean, A
Soyer, A
Bouchard, P
机构
[1] Denis Diderot Univ, Sch Dent, Dept Periodontol, Paris, France
[2] Dev Biol Lab, Paris, France
[3] Mineral Crystallog Lab, Paris, France
关键词
titanium; dental implants; air abrasion; comparison study;
D O I
10.1902/jop.1997.68.12.1215
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AN LN VITRO COMPARATIVE study was conducted in order to evaluate the effects of an air-abrasive system on dental implant surfaces. Eight new titanium dental implants, four standard machined implants (machined group), and four standard plasma-sprayed implants (plasma-sprayed group) were selected for investigation. Both neck and body surfaces of the implants were analyzed. Each pair of implants in each, group was treated as follows: the spray of the air-abrasive unit was applied to each area for 5 seconds on the first implant and 15 seconds on the second implant. A total of 24 areas were observed: 16 test implants and 8 controls. Scanning electron photomicrographs were analyzed by 3 examiners using a category rating scale (kappa = 0.594). The images were also computerized for texture analysis. The results indicate that a single air-powder abrasive treatment of the dental implants selected for this study modified their exposed surfaces. After treatment, the threaded neck surface of a machined group implant was least affected, whereas the body was the most altered. In the plasma-sprayed group, comparisons between implant surfaces showed little change. In the machined group, more change was observed in both neck and body areas. In all specimens, a 5-second exposure to the air-powder abrasive did not induce deep changes in the surfaces. A 15-second exposure modified all the specimen surfaces. Further studies are needed to evaluate the effect of these changes on the biological osseointegration process.
引用
收藏
页码:1215 / 1222
页数:8
相关论文
共 26 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]  
Alcoforado G A, 1991, J Parodontol, V10, P11
[3]  
Barnes C M, 1991, Int J Oral Maxillofac Implants, V6, P463
[4]  
BECKER W, 1990, International Journal of Oral and Maxillofacial Implants, V5, P31
[5]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[6]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[7]   CONTAMINATED IMPLANT SURFACES - AN IN-VITRO COMPARISON OF IMPLANT SURFACE COATING AND TREATMENT MODALITIES FOR DECONTAMINATION [J].
DENNISON, DK ;
HUERZELER, MB ;
QUINONES, C ;
CAFFESSE, RG .
JOURNAL OF PERIODONTOLOGY, 1994, 65 (10) :942-948
[8]  
Gonzales RafaelC., 1987, DIGITAL IMAGE PROCES, VSecond
[9]   EFFECT OF HYGIENE INSTRUMENTATION ON TITANIUM ABUTMENTS - A SCANNING ELECTRON-MICROSCOPY STUDY [J].
HOMIAK, AW ;
COOK, PA ;
DEBOER, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (03) :364-369
[10]   Digital image ratio: A new radiographic method for quantifying changes in alveolar bone .1. Theory and methodology [J].
Jean, A ;
Epelboin, Y ;
Rimsky, A ;
Soyer, A ;
Ouhayoun, JP .
JOURNAL OF PERIODONTAL RESEARCH, 1996, 31 (03) :161-167