Six months clinical, angiographic, and IVUS follow-up after PTFE graft stent implantation in native coronary arteries

被引:21
作者
Lukito, G [1 ]
Vandergoten, P [1 ]
Jaspers, L [1 ]
Dendale, P [1 ]
Benit, E [1 ]
机构
[1] Virga Jesse Hosp, Heart Ctr Hasselt, Dept Cardiol, B-3500 Hasselt, Belgium
关键词
PTFE graft stent; restenosis;
D O I
10.2143/AC.55.4.2005748
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction - Restenosis remains a problem even after stent implantation. An important breakthrough could be the use of graft stents, functioning as a mechanical barrier between the blood flow and the vessel wall, and possibly inducing less restenosis by more limited hyperplasia and minimal transgraft tissue penetration. Objective - To assess the acute and 6 months clinical, angiographic and IVUS results of a new balloon expandable coronary polytetrafluoroethylene (PTFE) graft stent (Jomed(R)). Method - Ten patients with a short (less than or equal to 15 mm length) de novo proximal stenosis in a large (greater than or equal to 3 mm diameter) coronary artery were treated by elective implantation of a graft stent (19 mm stent, 15 mm graft). Clinical assessment, quantitative coronary angiography (QCA) and intracoronary ultrasound (IVUS) were performed before, immediately after and 6 months after implantation. A stress test was also done at 6 months. Results - The coronary arteries treated were: RCA in 7 patients, LCX in 2 patients, LAD in 1 patient. Mean balloon size was 3.7 mm diameter, and mean inflation pressure was 18 atm (min. 12, max. 23). Additional stenting was needed in 3 patients. Two patients showed a minimal rise in CK (< 250 IU/I) and 1 patient needed a transfusion. No patient experienced a (sub)acute nor late thrombosis. As shown in the table, no restenosis was seen in the body of the graft stent, in 2 patients a restenosis was detected in the proximal and/or distal parts of the stent which are not covered by the graft. In 1 patient a restenosis was found outside the stent. All patients remained asymptomatic with a negative stress test at 6 months follow-up (FU).
引用
收藏
页码:255 / 260
页数:8
相关论文
共 14 条
[1]  
Di Mario C, 1999, CATHETER CARDIO INTE, V46, P463, DOI 10.1002/(SICI)1522-726X(199904)46:4<463::AID-CCD17>3.0.CO
[2]  
2-I
[3]   Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog [J].
Dolmatch, BL ;
Tio, FO ;
Li, XD ;
Dong, YH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (05) :641-649
[4]  
ELSEN M, 1998, EUR HEART J, V19, P2820
[5]   Perforation and rupture of coronary arteries [J].
Elsner, M ;
Zeiher, AM .
HERZ, 1998, 23 (05) :311-318
[6]  
Eton D, 1996, CIRCULATION, V94, P182
[7]  
GERCKENS U, 1998, JACC SA, V31, P1163
[8]  
GERCKENS U, 1998, INT J CARDIOVASCULAR, V1, P68
[9]  
Heuser RR, 1999, CATHETER CARDIO INTE, V46, P113, DOI 10.1002/(SICI)1522-726X(199901)46:1<113::AID-CCD28>3.3.CO
[10]  
2-Z