Comparative atomic force and scanning electron microscopy: An investigation on fenestrated endothelial cells in vitro

被引:43
作者
Braet, F
Kalle, WHJ
DeZanger, RB
DeGrooth, BG
Raap, AK
Tanke, HJ
Wisse, E
机构
[1] LEIDEN STATE UNIV,DEPT CELL BIOL,LAB CYTOCHEM & CYTOMETRY,2333 AL LEIDEN,NETHERLANDS
[2] TWENTE UNIV TECHNOL,DEPT APPL PHYS,7500 AE ENSCHEDE,NETHERLANDS
来源
JOURNAL OF MICROSCOPY-OXFORD | 1996年 / 181卷
关键词
liver; endothelial cells; fenestrae; sieve plates; serotonin; ethanol; cytochalasin B; scanning electron microscopy; atomic force microscopy; image analysis;
D O I
10.1046/j.1365-2818.1996.72348.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Rat liver sinusoidal endothelial cells (LEG) contain fenestrae, which are clustered in sieve plates, Fenestrae control the exchange of fluids, solutes and particles between the sinusoidal blood and the space of Disse, which at its back side is flanked by the microvillous surface of the parenchymal cells. The surface of LEC can optimally be imaged by scanning electron microscopy (SEM), and SEM images can be used to study dynamic changes in fenestrae by comparing fixed specimens subjected to different experimental conditions. Unfortunately, the SEM allows only investigation of fixed, dried and coated specimens, Recently, the use of atomic force microscopy (AFM) was introduced for analysing the cell surface, independent of complicated preparation techniques, We used the AFM for the investigation of cultured LEC surfaces and the study of morphological changes of fenestrae, SEM served as a conventional reference. AFM images of LEC show structures that correlate well with SEM images. Dried-coated, dried-uncoated and wet-fixed LEC show a central bulging nucleus and flat fenestrated cellular processes, It was also possible to obtain height information which is not available in SEM, After treatment with ethanol or serotonin the diameters of fenestrae increased (+6%) and decreased (-15%), respectively, The same alterations of fenestrae could be distinguished by measuring AFM images of dried-coated, dried-uncoated and wet-fixed LEG. Comparison of dried-coated (SEM) and wet-fixed (AFM) fenestrae indicated a mean shrinkage of 20% in SEM preparations, In conclusion, high-resolution imaging with AFM of the cell surface of cultured LEC can be performed on dried-coated, dried-uncoated and wet-fixed LEG, which was hitherto only possible with fixed, dried and coated preparations in SEM and transmission electron microscopy (TEM).
引用
收藏
页码:10 / 17
页数:8
相关论文
共 36 条
[1]  
[Anonymous], 1982, SINUSOIDAL LIVER CEL
[2]  
Arias I M, 1990, Prog Liver Dis, V9, P11
[3]   SHEAR STRESS-INDUCED REORGANIZATION OF THE SURFACE-TOPOGRAPHY OF LIVING ENDOTHELIAL-CELLS IMAGED BY ATOMIC-FORCE MICROSCOPY [J].
BARBEE, KA ;
DAVIES, PF ;
LAL, R .
CIRCULATION RESEARCH, 1994, 74 (01) :163-171
[4]  
BECKMANN M, 1994, J MEMBRANE BIOL, V140, P197
[5]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[6]  
Boyde A., 1984, SCAN ELECT MICROSC, V1, P71
[7]  
BRAET F, 1995, HEPATOLOGY, V21, P180, DOI 10.1002/hep.1840210130
[8]  
BRAET F, 1994, LAB INVEST, V70, P944
[9]   PRIMARY CULTURES OF ENDOTHELIAL-CELLS OF THE RAT-LIVER - A MODEL FOR ULTRASTRUCTURAL AND FUNCTIONAL-STUDIES [J].
DELEEUW, AM ;
BARELDS, RJ ;
DEZANGER, R ;
KNOOK, DL .
CELL AND TISSUE RESEARCH, 1982, 223 (01) :201-215
[10]  
DELEEUW AM, 1990, J ELECTRON MICR TECH, V14, P218