Rapid detection of trace Salmonella in milk and chicken by immunomagnetic separation in combination with a chemiluminescence microparticle immunoassay

被引:53
作者
Li, Jingwen [1 ]
Liu, Qingjun [1 ]
Wan, Yuping [2 ]
Wu, Xiaosheng [2 ]
Yang, Yin [1 ]
Zhao, Ruixue [1 ]
Chen, Erning [1 ]
Cheng, Xiaoyan [1 ]
Du, Meihong [1 ]
机构
[1] Beijing Ctr Phys & Chem Anal, Beijing Engn Res Ctr Food Safety Anal, Beijing Engn Technol Res Ctr Gene Sequencing & Ge, Beijing 100089, Peoples R China
[2] Beijing Kwinbon Biotechnol Co Ltd, Beijing Engn Res Ctr Food Safety Immune Rapid Det, Beijing 102206, Peoples R China
关键词
Pretreatment; Pathogen; Chemiluminescence immunoassay; Enrichment; Food safety; LINKED-IMMUNOSORBENT-ASSAY; FOODBORNE PATHOGENS; MAGNETIC NANOPARTICLES; LISTERIA-MONOCYTOGENES; FOOD; BACTERIA; SYSTEM; AMPLIFICATION; TYPHIMURIUM; BIOSENSORS;
D O I
10.1007/s00216-019-01991-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid detection of trace Salmonella is urgently needed to ensure food safety. We present an innovative pretreatment strategy, based on a two-step enrichment culture and immunomagnetic separation, combined with a chemiluminescence microparticle immunoassay to detect at least one proliferative Salmonella cell in 25 mL (25 g) food. The capture performance of immunomagnetic beads (IMBs) of sizes for Salmonella was investigated, and the IMBs of size 2.8 mu m showed a high capture efficiency of 60.7% in 25 mL milk and 74.5% in 25 mL chicken culture filtrate, which ensured the successful capture of trace Salmonella after 2.5 h in situ enrichment even from only one Salmonella cell. The separated Salmonella cells, reaching an amount of 10(3) colony-forming units (CFU) by a secondary enrichment for 3 h, were detected by a horseradish peroxidase chemiluminescence reaction with 4-(1-imidazolyl)phenol as an enhancer, which evidenced a linear response for Salmonella concentrations ranging from 2.3 x 10(2) to 7.8 x 10(4) CFU/mL. The entire detection process was completed within 8 h, with a very low detection limit of 1 CFU/25 mL (25 g), which was verified by colony counting, and a small degree of interference of 0.17-1.06%. Trace Salmonella from five different serovars in milk and chicken was successfully detected without false negative or false positive results. Furthermore, this study provides a basis to develop a fully automated instrument based on IMBs that includes all steps from sample preparation to chemiluminescence microparticle immunoassay for high-throughput screening of foodborne pathogens. Graphical abstract
引用
收藏
页码:6067 / 6080
页数:14
相关论文
共 53 条
[1]   Aptamer-conjugated silver nanoparticles for electrochemical dual-aptamer-based sandwich detection of staphylococcus aureus [J].
Abbaspour, Abdolkarim ;
Norouz-Sarvestani, Fatemeh ;
Noon, Abolhassan ;
Soltani, Noushin .
BIOSENSORS & BIOELECTRONICS, 2015, 68 :149-155
[2]   Electrochemical detection of Salmonella using gold nanoparticles [J].
Afonso, Andre S. ;
Perez-Lopez, Briza ;
Faria, Ronaldo C. ;
Mattoso, Luiz H. C. ;
Hernandez-Herrero, Manuela ;
Xavier Roig-Sagues, Artur ;
Maltez-da Costa, Marisa ;
Merkoci, Arben .
BIOSENSORS & BIOELECTRONICS, 2013, 40 (01) :121-126
[3]   Influence of milk product type and its initial contamination on the efficiency of different methods for detection of Salmonella Enteritidis, Listeria monocytogenes and Escherichia coli O157:H7 [J].
Antunovic, Boris ;
Kovacek, Ivancica ;
Gvozdanovic, Kristina ;
Grcevic, Manuela ;
Gantner, Vesna ;
Poljak, Vedran ;
Ostovic, Mario ;
Pavicic, Zeljko ;
Ahmetovic, Nihada .
MLJEKARSTVO, 2018, 68 (01) :3-11
[4]   Multiplexed detection of foodborne pathogens based on magnetic particles [J].
Brandao, Delfina ;
Liebana, Susana ;
Isabel Pividori, Maria .
NEW BIOTECHNOLOGY, 2015, 32 (05) :511-520
[5]   Effect of immunomagnetic bead size on recovery of foodborne pathogenic bacteria [J].
Chen, Jing ;
Park, Bosoon .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2018, 267 :1-8
[6]   In-situ fluorescent immunomagnetic multiplex detection of foodborne pathogens in very low numbers [J].
Cho, Il-Hoon ;
Mauer, Lisa ;
Irudayaraj, Joseph .
BIOSENSORS & BIOELECTRONICS, 2014, 57 :143-148
[7]   The development of methods for the detection of Salmonella in chickens by a combination of immunomagnetic separation and PCRs [J].
Dai, Fengying ;
Zhang, Miao ;
Xu, Dixin ;
Yang, Yin ;
Wang, Jiaxiao ;
Li, Mingzhen ;
Du, Meihong .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2017, 64 (06) :888-894
[8]   Employment of 4-(1-imidazolyl)phenol as a luminol signal enhancer in a competitive-type chemiluminescence immunoassay and its comparison with the conventional antigen-horseradish peroxidase conjugate-based assay [J].
Dotsikas, Y ;
Loukas, YL .
ANALYTICA CHIMICA ACTA, 2004, 509 (01) :103-109
[9]   Effective pre-treatment technique based on immune-magnetic separation for rapid detection of trace levels of Salmonella in milk [J].
Du, Meihong ;
Li, Jingwen ;
Zhao, Ruixue ;
Yang, Yin ;
Wang, Yanfei ;
Ma, Kai ;
Cheng, Xiaoyan ;
Wan, Yuping ;
Wu, Xiaosheng .
FOOD CONTROL, 2018, 91 :92-99
[10]   Comparison of enzyme-linked immunomagnetic chemiluminescence with US Food and Drug Administration's Bacteriological Analytical Manual method for the detection of Escherichia coli O157:H7 [J].
Gehring, Andrew G. ;
Albin, David M. ;
Irwin, Peter L. ;
Reed, Sue A. ;
Tu, Shu-I .
JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 67 (03) :527-533