The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy

被引:109
作者
Scanlon, PH
Malhotra, R
Thomas, G
Foy, C
Kirkpatrick, JN
Lewis-Barned, N
Harney, B
Aldington, SJ
机构
[1] Cheltenham Gen Hosp, Gloucestershire Eye Unit, Cheltenham GL53 7AN, Glos, England
[2] Oxford Eye Hosp, Oxford, England
[3] Gloucestershire R&D Support Unit, Gloucester, England
[4] Northumbria NHS Trust, Northshields, Tyne & Wear, England
[5] Univ London Imperial Coll Sci Technol & Med, Retinopathy Grading Ctr, London, England
关键词
diabetic retinopathy; ophthalmoscopy; screening; digital photography; sensitivity and specificity;
D O I
10.1046/j.1464-5491.2003.00954.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the introduction of a community-based non-mydriatic and mydriatic digital photographic screening programme by measuring the sensitivity and specificity compared with a reference standard and assessing the added value of technician direct ophthalmoscopy. Methods Study patients had one-field, non-mydriatic, 45degrees digital imaging photography prior to mydriatic two-field digital imaging photography followed by technician ophthalmoscopy. Of these patients, 1549 were then examined by an experienced ophthalmologist using slit lamp biomicroscopy as a reference standard. The setting was general practices in Gloucestershire. Patients were selected by randomizing groups of patients (from within individual general practices) and 3611 patients were included in the study. Patients for reference standard examination were recruited from groups of patients on days when the ophthalmologist was able to attend. The main outcome measure was detection of referable diabetic retinopathy (DR) as defined by the Gloucestershire adaptation of the European Working Party guidelines. Results For mydriatic digital photography, the sensitivity was 87.8%, specificity was 86.1% and technical failure rate was 3.7%. Technician ophthalmoscopy did not alter these figures. For non-mydriatic photography, the sensitivity was 86.0%, specificity was 76.7% and technical failure rate was 19.7%. Conclusions Two-field mydriatic digital photography is an effective method of screening for referable diabetic retinopathy. Non-mydriatic digital photography has an unacceptable technical failure rate and low specificity.
引用
收藏
页码:467 / 474
页数:8
相关论文
共 27 条
[1]  
ALDINGTON SJ, 1995, DIABETOLOGIA, V38, P437, DOI 10.1007/BF00410281
[2]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P823
[3]  
[Anonymous], 1991, Diabet Med, V8, P263
[4]  
*BDA, 1997, RET PHOT SCREEN DIAB, P1
[5]  
CLIFFORD R, 1996, AUDIT CARE ADULT DIA
[6]  
*DOH, 2003, NAT SERV FRAM DIAB D, P1
[7]  
Evans J L, 1995, Coord Noteb, P1
[8]  
Facey K, 2002, ORG SERVICES DIABETI, P1
[9]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[10]  
George LD, 1998, DIABETIC MED, V15, P250, DOI 10.1002/(SICI)1096-9136(199803)15:3<250::AID-DIA565>3.3.CO