Direct injection high efficiency nebulizer-inductively coupled plasma mass spectrometry for analysis of petroleum samples

被引:82
作者
Kahen, K [1 ]
Strubinger, A [1 ]
Chirinos, JR [1 ]
Montaser, A [1 ]
机构
[1] George Washington Univ, Dept Chem, Washington, DC 20052 USA
基金
美国国家科学基金会;
关键词
DIHEN; ICPMS; flow injection analysis; organic solvents; principal component analysis;
D O I
10.1016/S0584-8547(02)00261-6
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Direct injection high efficiency nebulizer (DIHEN)-inductively coupled plasma mass spectrometry (ICPMS) is investigated for analysis of petroleum samples dissolved in volatile organic solvents. To minimize solvent loading, the solution uptake rate is reduced to 10 mul/min, far less than the level (85 mul/min) commonly used for aqueous sample introduction with the DIHEN, and oxygen is added to the nebulizer gas flow and outer flow of the ICR Factorial design is applied to investigate the effect of nebulizer tip position within the torch and the nebulizer and intermediate gas flow rates on the precision and the net signal intensity of the elements tested for multielemental analysis. Cluster analysis and principal component analysis are performed to distinguish the behavior of different isotopes, oxide species and doubly charged ions. The best operating conditions at a solution uptake rate of 10 mul/min are: RF power = 1500 W, nebulizer gas flow rate = 0.10-0.12 l/min, intermediate gas flow rate = 1.5 l/min and DIHEN tip position = 3-4 trim below the top of the torch intermediate tube. Acceptable recoveries (100 +/- 10%) and good precision (less than 3% relative standard deviation) are obtained for trace elemental analysis in organic matrices (a certified gas oil sample and a custom-made certified reference material) using flow injection analysis. Because of high blank levels, detection limits are 1-3 orders of magnitude higher for organic sample introduction than those acquired for aqueous solutions. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:397 / 413
页数:17
相关论文
共 58 条
[21]   Multi-element optimization of the operating parameters for inductively coupled plasma atomic emission spectrometry with a charge injection device detector for the analysis of samples dissolved in organic solvents [J].
Chirinos, J ;
Fernandez, A ;
Franquiz, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :995-1000
[22]   Mixed-gas inductively coupled plasma atomic emission spectrometry using a direct injection high efficiency nebulizer [J].
Chirinos, JR ;
Kahen, K ;
O'Brien, SE ;
Montaser, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :128-135
[23]   Waste reduction in inductively coupled plasma mass spectrometry using flow injection and a direct injection nebulizer [J].
Crain, JS ;
Kiely, JT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :525-527
[24]   TECHNIQUES FOR EVALUATING CONTROL OF AUTOMATED MULTI-DETERMINANT ANALYTICAL INSTRUMENTS BY COMPUTER [J].
FISHER, MT ;
LEE, J ;
MARA, MK .
ANALYST, 1986, 111 (11) :1225-1229
[26]   The potential of multivariate quality control as a diagnostic tool in geoanalysis [J].
Howarth, RJ ;
Coles, BJ ;
Ramsey, MH .
ANALYST, 2000, 125 (11) :2032-2037
[27]   Characterization of an inductively coupled plasma with xylene solutions introduced as monodisperse aerosols [J].
Lazar, AC ;
Farnsworth, PB .
ANALYTICAL CHEMISTRY, 1997, 69 (19) :3921-3929
[28]  
LIDE DR, 1995, CRC HDB CHEM PHYSICS
[29]   CLASSIFICATION OF EMISSION SPECTRAL-LINES IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY USING PRINCIPAL COMPONENT ANALYSIS [J].
LOPEZMOLINERO, A ;
CABALLERO, AV ;
CASTILLO, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (07) :677-682
[30]   Improving sensitivity for CE-ICP-MS using multicapillary parallel separation [J].
Majidi, V ;
Qvarnström, J ;
Tu, Q ;
Frech, W ;
Thomassen, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1933-1935