New three-dimensional echocardiographic system using digital radiofrequency data - Visualization and quantitative analysis of aortic valve dynamics with high resolution - Methods, feasibility, and initial clinical experience

被引:24
作者
Handke, M
Jahnke, C
Heinrichs, G
Schlegel, J
Vos, C
Schmitt, D
Bode, C
Geibel, A
机构
[1] Univ Freiburg, Dept Cardiol & Angiol, D-79106 Freiburg, Germany
[2] TomTec GmbH, Unterschleissheim, Germany
[3] Fraunhofer Inst, Ctr Competence Biomed Microdevices, St Ingbert, Germany
[4] Toshiba Co Ltd, Otawara, Japan
关键词
echocardiography; 3D; valve; aortic; imaging;
D O I
10.1161/01.CIR.0000077909.54159.B4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Common 3D systems have only limited spatial and temporal resolution (frame rate of 25 Hz). Thin structures such as cardiac valves are not imaged exactly; rapid movement patterns cannot be precisely recorded. The objective of the present project was to achieve radiofrequency (RF) data transmission to the 3D workstation to improve image resolution. Methods and Results-A commercially available echocardiographic system (5-MHz transesophageal echocardiography probe) with an integrated raw data interface enables transmission of RF data (up to 40 megabytes per second). A 3D data set may contain up to 3 gigabytes, so that all of the high-resolution ultrasound information of the 2D image is available. Frame rates of up to 168 Hz result in temporal resolution 6 times that of standard 3D systems. The applicability of the system and the image quality were tested in 10 patients. The structure of the aortic valve and the dynamic changes were depicted by volume rendering. The changes in the orifice areas were measured in frame-by-frame planimetry. The mean number of frames recorded per cardiac cycle was 122 +/- 16. The improved structural resolution enabled a detailed imaging of the morphology of the aortic cusps. The rapid systolic movement patterns were recorded with up to 51 frames. The high number of frames enabled creation of precise area-time diagrams. Thus, the individual phases of aortic valve movement (rapid opening, slow valve closing, and rapid valve closing) could be analyzed quantitatively. Conclusion-A 3D system based on RF data enables high-resolution imaging of cardiac movement patterns. This offers new perspectives for qualitative and quantitative analyses, especially of cardiac valves.
引用
收藏
页码:2876 / 2879
页数:4
相关论文
共 11 条
[1]   Feasibility, accuracy, and incremental value of intraoperative three-dimensional transesophageal echocardiography in valve surgery [J].
Abraham, TP ;
Warner, JG ;
Kon, ND ;
Lantz, PE ;
Fowle, KM ;
Brooker, RF ;
Ge, SP ;
Nomeir, AM ;
Kitzman, DW .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (12) :1577-1582
[2]  
Buck T, 1997, CIRCULATION, V96, P4286
[3]   In vivo analysis of aortic valve dynamics by transesophageal 3-dimensional echocardiography with high temporal resolution [J].
Handke, M ;
Heinrichs, G ;
Beyersdorf, F ;
Olschewski, M ;
Bode, C ;
Geibel, A .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (06) :1412-1419
[4]   Quantitative assessment of aortic stenosis by three-dimensional anyplane and three-dimensional volume-rendered echocardiography [J].
Handke, M ;
Schäfer, DM ;
Heinrichs, G ;
Magosaki, E ;
Geibel, A .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (01) :45-53
[5]  
Handke M, 2001, Eur J Echocardiogr, V2, P46, DOI 10.1053/euje.2000.0064
[6]   Impact of dynamic 3D transoesophageal echocardiography in the assessment of atrial septal defects and occlusion by the double-umbrella device (CardioSEAL) [J].
Maeno, YV ;
Benson, LN ;
Boutin, C .
CARDIOLOGY IN THE YOUNG, 1998, 8 (03) :368-378
[7]   3-DIMENSIONAL AND 4-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHIC IMAGING OF THE HEART AND AORTA IN HUMANS USING A COMPUTED TOMOGRAPHIC IMAGING PROBE [J].
PANDIAN, NG ;
NANDA, NC ;
SCHWARTZ, SL ;
FAN, P ;
CAO, QL ;
SANYAL, R ;
HSU, TL ;
MUMM, B ;
WOLLSCHLAGER, H ;
WEINTRAUB, A .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (06) :677-687
[8]   Real-time three-dimensional echocardiography for determining right ventricular stroke volume in an animal model of chronic right ventricular volume overload [J].
Shiota, T ;
Jones, M ;
Chikada, M ;
Fleishman, CE ;
Castellucci, JB ;
Cotter, B ;
DeMaria, AN ;
von Ramm, OT ;
Kisslo, J ;
Ryan, T ;
Sahn, DJ .
CIRCULATION, 1998, 97 (19) :1897-1900
[9]   NORMAL AORTIC-VALVE FUNCTION IN DOGS [J].
THUBRIKAR, M ;
HARRY, R ;
NOLAN, SP .
AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (04) :563-568
[10]  
Thubrikar M J, 1993, J Heart Valve Dis, V2, P653