The type of embolic protection does not influence the outcome in carotid artery stenting

被引:54
作者
Iyer, Vikram
de Donato, Gianmarco
Deloose, Koen
Peeters, Patrick
Castriota, Fausto
Cremonesi, Alberto
Setacci, Carlo
Bosiers, Marc
机构
[1] AZ St Blasius, Dept Vasc Surg, B-9200 Dendermonde, Belgium
[2] Univ Siena, Dept Vasc & Endovasc Surg, I-53100 Siena, Italy
[3] Imelda Hosp Bonheiden, Dept Cardiovasc & Thorac Surg, Bonheiden, Belgium
[4] Villa Maria Cecilia Hosp, Intervent Cardio Angiol Unit, Cotignola, Italy
关键词
D O I
10.1016/j.jvs.2007.04.053
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. The goal of this study was to review our experience with embolic protection devices (EPDs) during carotid artery stenting (CAS). Specifically, we aimed to verify their clinical effectiveness and to compare clinical outcomes between specific devices and types of EPDs. Methods. The CAS databases at four participating centers were reviewed. Adverse events were defined as death, stroke (> 24 hours), or transient ischemic attack (TIA) (< 24 hours). We compared the risk of procedural and 30-day events between patients treated with and without an EPD. We also compared these risks between different EPDs and between the different types of EPDs. Results. A total of 3160 CAS procedures using nine EPDs were analyzed. The risk of a procedural adverse event was 0.9% in protected and 2.3% in unprotected procedures (P=.12). Compared with the most frequently used device (FilterWire, Boston Scientific, Natick, Mass), there was no significant difference in the risk of procedural adverse events for any of the other EPDs. There was, however, an increased risk of 30-day adverse events with the Accunet (Abbott Vascular, Redwood, Calif) filter compared with the FilterWire (relative risk [RR] 2.67, confidence interval [CI] 1.41 to 5.04, P=.005). Pairwise comparison of proximal occlusion balloons to filters, distal occlusion balloons to filters, and proximal to distal occlusion balloons revealed no significant difference in the risk of procedural or 30-day adverse events. There was no significant difference in risk of procedural events between eccentric and concentric filters, however, the relative risk of eccentric compared with concentric filters at 30 days was 0.59 (unadjusted, CI 0.38 to 0.92, P=.04). This difference was still apparent after adjustment for risk factors (RR 0.61, CI 0.39 to 0.95, P=.06), but not after adjustment for risk factors and stent-type [(open-cell vs closed-cell) RR 0.76, CI 0.47 to 1.22, P=.51]. Conclusion: The use of EPDs is associated with a low risk of procedural adverse events. We were unable to detect significant differences in risks of procedural adverse events between different devices or types of devices. We speculate that the observed differences seen at 30 days are largely attributable to differences in stent-type used.
引用
收藏
页码:251 / 256
页数:6
相关论文
共 24 条
[1]   Does free cell area influence the outcome in carotid artery stenting? [J].
Bosiers, M. ;
de Donato, G. ;
Deloose, K. ;
Verbist, J. ;
Peeters, P. ;
Castriota, F. ;
Cremonesi, A. ;
Setacci, C. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2007, 33 (02) :135-141
[2]  
Bosiers M, 2003, J ENDOVASC THER, V10, P695, DOI 10.1583/1545-1550(2003)010<0695:BEWFEI>2.0.CO
[3]  
2
[4]  
Bosiers M, 2004, CAROTID INTERVENTION, V13, P173
[5]  
Brown MM, 2001, LANCET, V357, P1729
[6]   Protected carotid stenting - Clinical advantages and complications of embolic protection devices in 442 consecutive patients [J].
Cremonesi, A ;
Manetti, R ;
Setacci, F ;
Setacci, C ;
Castriota, F .
STROKE, 2003, 34 (08) :1936-1941
[7]   Do device characteristics impact outcome in carotid artery stenting? [J].
Hart, Joseph P. ;
Peeters, Patrick ;
Verbist, Jurgen ;
Deloose, Koen ;
Bosiers, Marc .
JOURNAL OF VASCULAR SURGERY, 2006, 44 (04) :725-730
[8]   Carotid artery stenting is associated with increased complications in octogenarians: 30-day stroke and death rates in the CREST lead-in phase [J].
Hobson, RW ;
Howard, VJ ;
Roubin, GS ;
Brott, TG ;
Ferguson, RD ;
Popma, JJ ;
Graham, DL ;
Howard, G .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (06) :1106-1110
[9]   Early outcome of carotid angioplasty and stenting with and without cerebral protection devices -: A systematic review of the literature [J].
Kastrup, A ;
Gröschel, K ;
Krapf, H ;
Brehm, BR ;
Dichgans, J ;
Schulz, JB .
STROKE, 2003, 34 (03) :813-819
[10]   Incidence of new brain lesions after carotid stenting with and without cerebral protection [J].
Kastrup, Andreas ;
Naegele, Thomas ;
Groeschel, Klaus ;
Schmidt, Friederike ;
Vogler, Eva ;
Schulz, Joerg ;
Ernemann, Ulrike .
STROKE, 2006, 37 (09) :2312-2316