摘要
A method using flow injection (FI) with amperometric detection at anodized boron-doped diamond (BDD) thin films has been developed and applied for the determination of tetracycline antibiotics (tetracycline, chlortetracycline, oxytetracycline and doxycycline). The electrochemical oxidation of the tetracycline antibiotics was studied at various carbon electrodes including glassy carbon (GC), as-deposited BDD and anodized BDD electrodes using cyclic voltammetry. The anodized BDD electrode exhibited well-defined irreversible cyclic voltammograms for the oxidation of tetracycline antibiotics with the highest current signals compared to the as-deposited BDD and glassy carbon electrodes. Low detection limit of 10 nM (signal-to-noise ratio = 3) was achieved for each drug when using flow injection analysis with amperometric detection at anodized BDD electrodes. Linear calibrations were obtained from 0.1 to 50 mM for tetracycline and 0.5-50 mM for chlortetracycline, oxytetracycline and doxycycline. The proposed method has been successfully applied to determine the tetracycline antibiotics in some drug formulations. The results obtained in percent found (99.50-103.01%) were comparable to dose labeled. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1183 / 1188
页数:6
相关论文
共 35 条
[1]   The electrochemical oxidation of homocysteine at boron-doped diamond electrodes with application to HPLC amperometric detection [J].
Chailapakul, O ;
Siangproh, W ;
Sarada, BV ;
Terashima, C ;
Rao, TN ;
Tryk, DA ;
Fujishima, A .
ANALYST, 2002, 127 (09) :1164-1168
[2]   Tetracycline, oxytetracycline and chlortetracycline determination by flow injection potentiometry [J].
Couto, CMCM ;
Lima, JLFC ;
Conceiçao, M ;
Montenegro, BSM ;
Reis, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :527-533
[3]   SENSITIVE SPECTROFLUOROMETRIC DETERMINATION OF TETRACYCLINE RESIDUES IN BOVINE-MILK [J].
CROUBELS, S ;
VANPETEGHEM, C ;
BAEYENS, W .
ANALYST, 1994, 119 (12) :2713-2716
[4]   Ion chromatographic analysis of tetracyclines using polymeric column and acidic eluent [J].
Ding, XJ ;
Mou, SF .
JOURNAL OF CHROMATOGRAPHY A, 2000, 897 (1-2) :205-214
[5]   SPECTROPHOTOMETRIC DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE IN PHARMACEUTICAL PREPARATIONS [J].
EMARA, KM ;
ASKAL, HF ;
SALEH, GA .
TALANTA, 1991, 38 (11) :1219-1221
[6]   Polycrystalline diamond electrodes: basic properties and applications as amperometric detectors in flow injection analysis and liquid chromatography [J].
Granger, MC ;
Xu, JS ;
Strojek, JW ;
Swain, GM .
ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) :145-161
[7]   CONTINUOUS-FLOW CHEMILUMINOMETRIC DETERMINATION OF TETRACYCLINES IN PHARMACEUTICAL PREPARATIONS AND HONEY BY OXIDATION WITH N-BROMOSUCCINIMIDE [J].
HALVATZIS, SA ;
TIMOTHEOUPOTAMIA, MM ;
CALOKERINOS, AC .
ANALYST, 1993, 118 (06) :633-637
[8]   Chemiluminescence determination of tetracyclines using a tris(2,2′-bipyridine)ruthenium(II) and potassium permanganate system [J].
Han, HY ;
He, ZK ;
Zeng, Y .
ANALYTICAL SCIENCES, 1999, 15 (05) :467-470
[9]   Electrochemical detection of tricyclic antidepressant drugs by HPLC using highly boron-doped diamond electrodes [J].
Ivandini, TA ;
Sarada, BV ;
Terashima, C ;
Rao, TN ;
Tryk, DA ;
Ishiguro, H ;
Kubota, Y ;
Fujishima, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 521 (1-2) :117-126
[10]   FLOW-INJECTION AMPEROMETRIC DETECTION BASED ON ION TRANSFER ACROSS A WATER-SOLIDIFIED NITROBENZENE INTERFACE FOR THE DETERMINATION OF TETRACYCLINE AND TERRAMYCIN [J].
JI, HM ;
WANG, EK .
ANALYST, 1988, 113 (10) :1541-1543