Optimal location of shunt FACTS devices in long transmission lines

被引:26
作者
Haque, MH [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 2263, Singapore
关键词
D O I
10.1049/ip-gtd:20000412
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
FACTS devices are now recognised as a viable solution for controlling transmission voltage, power flow, dynamic response, etc. and represent a new era for transmission systems. It has been proved that the centre or midpoint of a transmission line is the optimal location for shunt FACTS devices or reactive power support and the proof is based on the simplified line model. The validity of the above optimal location of shunt FACTS devices is investigated, when the actual model of the line is considered. It is found that the FACTS device needs to be placed slightly off-centre to get the highest possible benefit. Both the power transfer capability and stability of the system can further be improved if the shunt FACTS device is placed at the new optimal point instead of at the midpoint of a line having some resistance. This finding contradicts the previous results found for the simplified line model.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 14 条
[1]  
Anderson J.G., 1982, Transmission line reference book 345 KV and above, P545
[2]   Block diagram model for fundamental studies of a synchronous generator-static VAr compensator system [J].
Aree, P ;
Acha, E .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (05) :507-514
[3]   Proposed terms and definitions for flexible ac transmission system (FACTS) [J].
Edris, AA ;
Adapa, R ;
Baker, MH ;
Clark, LBK ;
Habashi, K ;
Gyugyi, L ;
Lemay, J ;
Mehraban, AS ;
Myers, AK ;
Reeve, J ;
Sener, F ;
Torgerson, DR ;
Wood, RR .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) :1848-1853
[4]  
Glover J. D., 1994, POWER SYSTEM ANAL DE
[5]   THE UNIFIED POWER-FLOW CONTROLLER - A NEW APPROACH TO POWER TRANSMISSION CONTROL [J].
GYUGYI, L ;
SCHAUDER, CD ;
WILLIAMS, SL ;
RIETMAN, TR ;
TORGERSON, DR ;
EDRIS, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) :1085-1097
[6]   UNIFIED POWER-FLOW CONTROL CONCEPT FOR FLEXIBLE AC TRANSMISSION-SYSTEMS [J].
GYUGYI, L .
IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1992, 139 (04) :323-331
[7]   HOW TO IMPROVE SYSTEM STABILITY WITHOUT RISKING SUBSYNCHRONOUS RESONANCE [J].
KIMBARK, EW .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (05) :1608-1619
[8]   Flexible AC transmission systems .2. Methods of transmission line compensation [J].
Moore, P ;
Ashmole, P .
POWER ENGINEERING JOURNAL, 1996, 10 (06) :273-278
[9]   Mid-point siting of FACTS devices in transmission lines [J].
Ooi, BT ;
Kazerani, M ;
Marceau, R ;
Wolanski, Z ;
Galiana, FD ;
McGillis, D ;
Joos, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) :1717-1722
[10]   UPFC application on the AEP system: Planning considerations [J].
Rahman, M ;
Ahmed, M ;
Gutman, R ;
OKeefe, RJ ;
Nelson, RJ ;
Bian, JH .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (04) :1695-1701