Application of a new portable microscopic somatic cell counter with disposable plastic chip for milk analysis

被引:49
作者
Moon, J. S.
Koo, H. C.
Joo, Y. S.
Jeon, S. H.
Hur, D. S.
Chung, C. I.
Jo, H. S.
Park, Y. H. [1 ]
机构
[1] Seoul Natl Univ, Dept Microbiol, Coll Vet Med, Seoul, South Korea
[2] Seoul Natl Univ, Program Vet Sci BK21, Seoul, South Korea
[3] Digital Bio Technol Co Ltd, Seoul, South Korea
[4] Seoul Natl Univ, KRF Zoonot Dis Prior Res Inst, Seoul, South Korea
[5] Natl Vet Res & Quarantine Serv, Dept Bacteriol, Anyang, Gyeonggi Do, South Korea
关键词
bovine raw milk; somatic cell count; C-reader; disposable plastic microchip;
D O I
10.3168/jds.2006-622
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The somatic cell count (SCC) is one of the international standards for monitoring milk quality, and it is a useful indicator of mastitis. The current reference method for determining the SCC in raw milk is direct microscopic analysis, but this method requires well-trained staff to maintain its accuracy and reproducibility. To overcome these inconveniences, we developed a portable system (the C-reader system) that utilizes the capillary flow of a microfluidic chamber by surface modification of the hydrophilicity. The microfluidic technology of disposable microchips allows for low consumption of reagents, and a combination of ready-to-use reagents makes the daily work easier. The repeatability test of the C-reader using 10 composite bovine milk samples satisfied the recommended values for SCC equipment. In addition, an acceptable accuracy level of the natural logarithmic-transformed SCC [ln(SCC/1,000): +/- 0.059 to 0.112] was achieved using composite raw milk samples and various somatic cell standard solutions from the American Eastern Laboratory and the Korean National Veterinary Research and Quarantine Service. After testing 875 composite milk samples, the C-reader showed a high correlation coefficient (R-2 = 0.935 to 0.964) and a low mean difference value in log-transformed SCC (-0.088 to 0.004) compared with 3 automatic commercialized somatic cell counters (Fossomatic 4000, Somacount 150, and Somascope). In conclusion, the C-reader system is a new, easy-to-use automatic on-farm method with acceptable repeatability and accuracy for measuring SCC in large dairies and smaller laboratories.
引用
收藏
页码:2253 / 2259
页数:7
相关论文
共 25 条
[1]  
ANDERS L, 2002, J COLLOID INTERF SCI, V246, P214
[2]  
CRARY B, 1986, Biotechniques, V4, P98
[3]   Impact of early lactation somatic cell count in heifers on somatic cell counts over the first lactation [J].
De Vliegher, S ;
Barkema, HW ;
Stryhn, H ;
Opsomer, G ;
de Kruif, A .
JOURNAL OF DAIRY SCIENCE, 2004, 87 (11) :3672-3682
[4]  
EMBERT H, 1986, VET CLIN PATHOL, P34
[5]  
FOREST HL, 1959, 15 P INT DAIR C, V3, P1883
[6]   Evaluation of rapid somatic cell counters under different analytical conditions in ovine milk [J].
Gonzalo, C ;
Boixo, JC ;
Carriedo, JA ;
San Primitivo, F .
JOURNAL OF DAIRY SCIENCE, 2004, 87 (11) :3623-3628
[7]   Potential for broad applications of flow cytometry and fluorescence techniques in microbiological and somatic cell analyses of milk [J].
Gunasekera, TS ;
Veal, DA ;
Attfield, PV .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2003, 85 (03) :269-279
[8]  
HINZ CW, 1992, STANDARD METHODS EXA, P334
[9]  
Ian Freshney R., 1993, CULTURE ANIMAL CELLS
[10]  
*IDF, 1999, 128A FILIDF