Enhancement of MR images using registration for signal averaging

被引:1109
作者
Holmes, CJ
Hoge, R
Collins, L
Woods, R
Toga, AW
Evans, AC
机构
[1] Univ Calif Los Angeles, Sch Med, Lab Neuroimaging, Los Angeles, CA 90024 USA
[2] McGill Univ, Montreal Neurol Inst, McConnel Brain Imaging Ctr, Montreal, PQ, Canada
关键词
brain; anatomy; atlas and atlases; image processing; magnetic resonance imaging; techniques;
D O I
10.1097/00004728-199803000-00032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: With the advent of noninvasive neuroimaging, a plethora of digital human neuroanatomical atlases has been developed. The accuracy of these atlases is constrained by the resolution and signal-gathering powers of available imaging equipment. In an attempt to circumvent these limitations and to produce a high resolution in vivo human neuroanatomy, we investigated the usefulness of intrasubject registration for post hoc MR signal averaging. Method: Twenty-seven high resolution (7 x 0.78 and 20 x 1.0 mm(3)) T1-weighted volumes were acquired from a single subject, along with 12 double echo T2/proton density-weighted volumes. These volumes were automatically registered to a common stereotaxic space in which they were subsampled and intensity averaged. The resulting images were examined for anatomical quality and usefulness for other analytical techniques. Results: The quality of the resulting image from the combination of as few as five T1 volumes was visibly enhanced. The signal-to-noise ratio was expected to increase as the root of the number of contributing scans to 5.2, n = 27. The improvement in the n = 27 average was great enough that fine anatomical details, such as thalamic subnuclei and the gray bridges between the caudate and putamen, became crisply defined. The gray/white matter boundaries were also enhanced, as was the visibility of any finer structure that was surrounded by tissue of varying T1 intensity. The T2 and proton density average images were also of higher quality than single scans, but the improvement was not as dramatic as that of the T1 volumes. Conclusion: Overall, the enhanced signal in the averaged images resulted in higher quality anatomical images, and the data lent themselves to several postprocessing techniques. The high quality of the enhanced images permits novel uses of the data and extends the possibilities for in vivo human neuroanatomy.
引用
收藏
页码:324 / 333
页数:10
相关论文
共 38 条
  • [1] [Anonymous], 1967, ATLAS ANATOMIE STERE
  • [2] SURFACE COIL MAGNETIC-RESONANCE-IMAGING
    AXEL, L
    HAYES, C
    [J]. ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1985, 93 (05): : 11 - 18
  • [3] A COMPUTERIZED ADJUSTABLE BRAIN ATLAS
    BOHM, C
    GREITZ, T
    ERIKSSON, L
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11): : 687 - 689
  • [4] AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE
    COLLINS, DL
    NEELIN, P
    PETERS, TM
    EVANS, AC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 192 - 205
  • [5] Automatic 3-D model-based neuroanatomical segmentation
    Collins, DL
    Holmes, CJ
    Peters, TM
    Evans, AC
    [J]. HUMAN BRAIN MAPPING, 1995, 3 (03) : 190 - 208
  • [6] EDELSTEIN WA, 1985, JAMA-J AM MED ASSOC, V25, P828
  • [7] ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY
    EVANS, AC
    BEIL, C
    MARRETT, S
    THOMPSON, CJ
    HAKIM, A
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) : 513 - 530
  • [8] EVANS AC, 1993, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE, VOLS 1-3, P1813, DOI 10.1109/NSSMIC.1993.373602
  • [9] EVANS AC, 1994, NATO ADV SCI INST SE, V264, P263
  • [10] EVANS AC, 1991, SPIE, V1445, P236