Potential sources of error in capillary electrophoresis inductively coupled plasma mass spectrometry for chemical speciation

被引:38
作者
Majidi, V
Miller-Ihli, NJ
机构
[1] Univ Calif Los Alamos Natl Lab, Chem Sci & Technol Div CST9, Los Alamos, NM 87545 USA
[2] USDA ARS, Beltsville Agr Res Ctr, Beltsville Human Nutr Res Ctr, Food Composit Lab, Beltsville, MD 20705 USA
关键词
speciation; capillary electrophoresis; elemental mass spectrometry; cyanocobalamin; rabbit metallothionein; coenzyme-B-12;
D O I
10.1039/a708256h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The distribution concentration of chemical species in a sample is dictated by the physical and chemical properties of the matrix. As such, when a sample is pre-treated, in any way, there is a potential for redistribution of homologous species. The extent of this analyte redistribution is determined by both thermodynamic properties of species (e.g., changes in concentrations of species according to their equilibrium expressions) and kinetic properties (e.g., the rate of the reactions compared with the duration of sample preparation and analysis). The redistributions of analyte species as a function of several experimental parameters (e.g., time, solution pH, injection methods and calibration methods) are illustrated in this paper, Whereas rabbit metallothionein protein showed a stability of more than a few days under certain storage conditions, coenzyme-B-12 was rapidly degraded in less than 2 h, pH studies showed that the migration of free Cd2+ ions in rabbit metallothionein was not significantly affected unless the pH of the solution exceeds the solubility limit of the metal hydroxide, However, pH-sensitive compounds such as vitamin B-12 showed significant changes in the migration time and analyte composition. The injection studies suggested that electrokinetic injection may produce biased results, in favor of species that have higher electrophoretic mobility. Hydrodynamic injection will produce a result that is more representative of the initial sample composition.
引用
收藏
页码:809 / 813
页数:5
相关论文
共 19 条
[11]   Ion spray mass spectrometry for elemental speciation in aqueous samples: Preliminary investigation of experimental parameters, matrix effects and metal-ligand complexation [J].
Olesik, JW ;
Thaxton, KK ;
Olesik, SV .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) :507-515
[12]   Determination of ten organoarsenic compounds using microbore high-performance liquid chromatography coupled with electrospray mass spectrometry mass spectrometry [J].
Pergantis, SA ;
Winnik, W ;
Betowski, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) :531-536
[14]   APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS TO THE SEPARATION OF METALLOTHIONEIN ISOFORMS [J].
RICHARDS, MP ;
BEATTIE, JH ;
SELF, R .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10) :2113-2128
[15]   Investigations into chromium speciation by electrospray mass spectrometry [J].
Stewart, II ;
Horlick, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1203-1214
[16]  
SZPUNAR J, 1997, 43 INT C AN SCI SPEC
[17]   The positive roles of metallic droplets in deposition of alloy films by cathodic arc plasma deposition [J].
Wang, SG ;
Bai, XD ;
Wang, BC ;
Fan, YD .
JOURNAL OF MATERIALS RESEARCH, 1996, 11 (05) :1137-1143
[18]   First order speciation of As using flow injection hydride generation atomic absorption spectrometry with in-situ trapping of the arsine in a graphite furnace [J].
Willie, SN .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) :1781-1790
[19]  
WINDHOLZ M, 1976, MERCK INDEX, P1287