Investigation of the concentration of bacteria and their cell envelope components in indoor air in two elementary schools

被引:54
作者
Liu, LJS [1 ]
Krahmer, M
Fox, A
Feigley, CE
Featherstone, A
Saraf, A
Larsson, L
机构
[1] Univ Washington, Dept Environm Hlth, Seattle, WA 98195 USA
[2] Univ S Carolina, Dept Environm Hlth Sci, Columbia, SC 29208 USA
[3] Lund Univ, Dept Med Microbiol, S-22100 Lund, Sweden
关键词
D O I
10.1080/10473289.2000.10464225
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bacterial cell envelope components are widely distributed in airborne dust, where they act as inflammatory agents causing respiratory symptoms. Measurements of these agents and ether environmental factors are assessed in two elementary schools in a southeastern city in the United States. Muramic acid (MA) was used as a marker for bacterial peptidoglycan (PG), and 3-hydroxy fatty acids (3-OH FAs) were used as markers for Gram-negative bacterial lipopolysaccharide (LPS). Culturable bacteria were collected using an Andersen sampler with three different culture media. In addition, temperature (T), relative humidity (RH), and CO2 were continuously monitored. Concentrations of airborne MA and 3-OH FAs were correlated with total suspended particulate (TSP) levels. Outdoor MA (mean = 0.78-1.15 ng/m(3)) and 3-OH FA levels (mean = 2.19-2.18 ng/m(3)) were similar at the two schools. Indoor concentrations of airborne MA and 3-OH FAs differed significantly between schools (MA: 1.44 vs. 2.84 ng/m3; 3-OH FAs: 2.96 vs. 4.57 ng/m(3)). Although indoor MA levels were low, they were significantly related to teachers' perception of the severity of indoor air quality (IAQ) problems in their classrooms. Concentrations of CO2 correlated significantly with all bacteria measurements. Because CO2 levels were related to the number of occupants and the ventilation rates, these findings are consistent with the hypothesis that the children and teachers are sources of bacterial contamination. Many culturable bacteria present in indoor air are opportunistic organisms that can be infectious for compromised individuals, while both culturable and nonculturable bacterial remnants act as environmental toxins for both healthy and compromised individuals. Measuring the "total bacteria load" would be most accurate in assessing the biotoxicity of indoor air. Chemical analysis of MA and 3-OH FAs, when coupled with the conventional culture method, provides complementary information for assessing biocontamination of indoor air.
引用
收藏
页码:1957 / 1967
页数:11
相关论文
共 70 条
[1]  
*AAA ENV, 1995, UNPUB IND AIR SURV R
[2]  
[Anonymous], 1993, INDOOR AIR, DOI DOI 10.1111/J.1600-0668.1993.00005.X
[3]  
[Anonymous], 1988, Microbial Lipids
[4]  
*AZ INC, 1992, UNPUB IND AIR QUAL S
[5]   BACTERIAL SPORE HEAT-RESISTANCE CORRELATED WITH WATER-CONTENT, WET DENSITY, AND PROTOPLAST SPOROPLAST VOLUME RATIO [J].
BEAMAN, TC ;
GREENAMYRE, JT ;
CORNER, TR ;
PANKRATZ, HS ;
GERHARDT, P .
JOURNAL OF BACTERIOLOGY, 1982, 150 (02) :870-877
[6]   POLYMERASE CHAIN REACTION-GENE PROBE DETECTION OF MICROORGANISMS BY USING FILTER-CONCENTRATED SAMPLES [J].
BEJ, AK ;
MAHBUBANI, MH ;
DICESARE, JL ;
ATLAS, RM .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (12) :3529-3534
[7]  
*BUR NAT AFF, 1990, OCC SAF HLTH ADM TEC, pCH6
[8]   Limitations of a home characteristics questionnaire as a predictor of indoor allergen levels [J].
Chew, GL ;
Burge, HA ;
Dockery, DW ;
Muilenberg, ML ;
Weiss, ST ;
Gold, DR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (05) :1536-1541
[9]   COTTON DUST AND GRAM-NEGATIVE BACTERIAL-ENDOTOXIN CORRELATIONS IN 2 COTTON TEXTILE MILLS [J].
CHRISTIANI, DC ;
WEGMAN, DH ;
EISEN, EA ;
YE, TT ;
LU, PL ;
OLENCHOCK, SA .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1993, 23 (02) :333-342
[10]  
*CLEAN AIR INC, 1995, AIR TEST REP