Objectives. We tested the hypothesis that ischemic myocardium can be sensitively detected using tissue Doppler-derived myocardial velocity gradient (MVG) by a dobutamine challenge. Background. Although tissue Doppler imaging (TDI) has recently emerged to quantify regional myocardial contraction, in creased translational motion during a dobutamine challenge may affect the measurements. MVG is an indicator of regional myocardial contraction independent of the translational motion. Methods. We studied 19 patients with (n = 13) and without (n = 6) confirmed single-vessel coronary artery disease. Left ventricular short-axis tissue Doppler images were obtained along with conventional echocardiograms during a submaximal two-step dobutamine challenge (10 and 30 mu g/kg body weight per min). Endocardial velocity as well as MVG were derived from TDI using computer analysis in the anteroseptal and posterior segments and were compared with visual interpretation. Results. MVG demonstrated a significant dose-responsive increase in the nonischemic segments (anteroseptal: 2.6 +/- 0.8/s to 6.0 +/- 1.0/s [mean +/- SD], p < 0.05; posterior: 3.9 +/- 0.7/s to 7.6 +/- 1.8/s, p < 0.05) but remained unchanged in the ischemic segments (anteroseptal: 2.5 +/- 0.8/s to 2.7 +/- 0.7/s, p = NS; posterior: 3.4 +/- 1.0/s to 4.1 +/- 0.9/s, p = NS). Endocardial velocity failed to clearly demonstrate the differing responses between the nonischemic (anteroseptal: -2.3 +/- 1.2 to -2.7 +/- 1.6 cm/s, p = NS; posterior: 3.8 +/- 1.1 to 7.3 +/- 2.7 cm/s, p < 0.05) and ischemic segments (anteroseptal: -2.1 +/- 0.5 to -2.8 +/- 0.8 cm/s, p = NS; posterior: 4.2 +/- 0.8 to 6.5 +/- 2.6 cm/s, p = NS). Wall motion abnormality was hardly detectable with visual interpretation (wall motion score range 1.00 to 1.33). Conclusions. Abnormal segments could be sensitively detected by using MVG in a submaximal dobutamine challenge, even where conventional methods failed to detect the abnormality. (C) 1998 by the American College of Cardiology.