Chromium(III) hexacyanoferrate(II)-based chemical sensor for the cathodic determination of hydrogen peroxide

被引:74
作者
Lin, MS [1 ]
Tseng, TF [1 ]
Shih, WC [1 ]
机构
[1] Tamkang Univ, Dept Chem, Tamsui 25137, Taiwan
关键词
chromium(III) hexacyanoferrate(II)-modified electrode; hydrogen peroxide; chemical sensors;
D O I
10.1039/a705207c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A cathodic scheme to measure hydrogen peroxide by utilizing a membrane free chromium(III) hexacyanoferrate(II) based chemical sensor is described. The cluster is prepared simply by generating a chromium(III) hexacyanoferrate(II) cluster electrochemically on a rotating disk glassy carbon electrode. Subsequently, the hydrogen peroxide can be measured at 0 V versus Ag/AgCl. This approach significantly reduces interferences, especially those by easy oxidizable compounds such as catechol and ascorbic acid. Also, no significant oxygen interference is observed at this working potential, Several electrolytes mere carefully investigated. The calibration curve was linear up to 1.3 mM (r = 0.9992) with a typical response of the sensor of about 5.6 s with injection of 0.05 mM hydrogen peroxide. The detection limit of this chemical sensor is 3.0 X 10(-8) M (S/N = 3) with a low-pass filter (time constant 0.1 s), The sensitivity of the sensor is 11.52 X 10(-6) A l mmol(-1) mm(-2) (r = 0.9992). The RSD of this sensor is 1.1%.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 30 条
[1]   FIBER-OPTIC SENSOR FOR THE DETERMINATION OF GLUCOSE USING MICELLAR ENHANCED CHEMI-LUMINESCENCE OF THE PEROXYOXALATE REACTION [J].
ABDELLATIF, MS ;
GUILBAULT, GG .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2671-2674
[2]   DIRECT AND TITRIMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BY REVERSE PULSE POLAROGRAPHY [J].
BRESTOVISKY, A ;
KIROWAEISNER, E ;
OSTERYOUNG, J .
ANALYTICAL CHEMISTRY, 1983, 55 (13) :2063-2066
[3]  
Brown D.M., 1980, Mixed Valence Compounds
[4]   SOLID-STATE REACTIONS OF IRON(2) HEXACYANOCHROMATE(3) [J].
BROWN, DB ;
SHRIVER, DF ;
SCHWARTZ, LH .
INORGANIC CHEMISTRY, 1968, 7 (01) :77-&
[5]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[6]   FLOW-THROUGH OPTICAL BIOSENSOR BASED ON THE PERMANENT IMMOBILIZATION OF AN ENZYME AND TRANSIENT RETENTION OF A REACTION-PRODUCT [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3048-3052
[7]   ELECTROCHEMICAL-BEHAVIOR OF CHROMIUM(III)-HEXACYANOFERRATE FILM-MODIFIED ELECTRODES - VOLTAMMETRIC AND ELECTROCHEMICAL IMPEDANCE STUDIES [J].
GAO, ZQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 370 (1-2) :95-102
[9]   FLUOROMETRIC-DETERMINATION OF HYDROGEN-PEROXIDE IN GROUNDWATER [J].
HOLM, TR ;
GEORGE, GK ;
BARCELONA, MJ .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :582-586
[10]   IMMOBILIZED LUMINOL CHEMI-LUMINESCENCE REAGENT SYSTEM FOR HYDROGEN-PEROXIDE DETERMINATIONS IN FLOWING STREAMS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :834-837