Laser Ablation-ICP-MS analysis of dissected tissue: A conservation-minded approach to assessing contaminant exposure

被引:27
作者
Jackson, BP [1 ]
Hopkins, WA [1 ]
Baionno, J [1 ]
机构
[1] Univ Georgia, Savannah River Ecol Lab, Aiken, SC 29802 USA
关键词
D O I
10.1021/es026416p
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Minimally invasive sampling techniques are an essential ecotoxicological tool for continuous assessment of contaminant exposure and in instances where it is not desirable or practical to sacrifice the animal. In this paper, we report on the application of laser ablation-ICP-MS (LA-ICP-MS) for sampling of minute (similar to1 mg, 2-3 mm) tail clips of the banded water snake, Nerodia fasciata, as a means to assess contaminant exposure. The snakes were split into three treatments (n = 8) and were fed three increasing levels (control, medium, and high) of fish contaminated with As, Se, and Sr for 24 months. LA-ICP-MS concentrations of tail clips for all three elements were significantly correlated with the remaining whole tail concentration determined by homogenization, acid digestion, and ICP-MS analysis. Additionally, LA-ICP-MS concentrations for As and Se in the tail clip were similar to the acid digestion solution analysis values for the whole tail, which suggests that these elements are homogeneously distributed. Strontium concentrations were underestimated by LA-ICP-MS when compared to whole tail concentrations. Statistical analysis showed that LA-ICP-MS tail clip concentrations differed significantly according to dietary treatment. Posterior probability error rates from nonparametric discriminant function analysis indicated that LA-ICP-MS analysis of tail clips was useful for predicting exposure to Se with only a 4% probability of misclassification among treatments. Errors associated with misclassification of As were greater (17%) but this was, in part, related to the low concentrations of As in the tail (< 1 ppm for the highest treatment). Taken together, the findings from this study suggest that LA-ICP-MS of microdissected tissue shows promise as a nondestructive technique for conservation-minded ecotoxicological studies.
引用
收藏
页码:2511 / 2515
页数:5
相关论文
共 17 条
[1]   Improvements in calibration procedures for the quantitative determination of trace elements in carbonate material (mussel shells) by laser ablation ICP-MS [J].
Bellotto, VR ;
Miekeley, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (07) :635-640
[2]   Inter-element fractionation and correction in laser ablation inductively coupled plasma mass spectrometry [J].
Chen, ZX .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1823-1828
[3]   An assessment of calibration strategies for the quantitative and semi-quantitative analysis of calcium carbonate matrices by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) [J].
Craig, CA ;
Jarvis, KE ;
Clarke, LJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :1001-1008
[4]  
Gibbons JW, 2000, BIOSCIENCE, V50, P653, DOI 10.1641/0006-3568(2000)050[0653:TGDORD]2.0.CO
[5]  
2
[6]   Spatial determination of elements in green leaves of oak trees (Quercus robur) by laser ablation-ICP-MS [J].
Hoffmann, E ;
Lüdke, C ;
Skole, J ;
Stephanowitz, H ;
Ullrich, E ;
Colditz, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (06) :579-585
[7]  
Hopkins WA, 2002, ENVIRON TOXICOL CHEM, V21, P906, DOI 10.1897/1551-5028(2002)021<0906:EOCDET>2.0.CO
[8]  
2
[9]   Nondestructive indices of trace element exposure in squamate reptiles [J].
Hopkins, WA ;
Roe, JH ;
Snodgrass, JW ;
Jackson, BP ;
Kling, DE ;
Rowe, CL ;
Congdon, JD .
ENVIRONMENTAL POLLUTION, 2001, 115 (01) :1-7
[10]   Ingestion of trace metals by the opossum shrimp, Mysis relicta, determined by laser ablation sampling -: inductively coupled plasma mass spectrometry [J].
Lasenby, DC ;
Veinott, G .
CANADIAN JOURNAL OF ZOOLOGY-REVUE CANADIENNE DE ZOOLOGIE, 1998, 76 (08) :1605-1610