Determination of chlorotriazines, methylthiotriazines and one methoxytriazine by SPE-LC-UV in water samples

被引:13
作者
Dopico, MS [1 ]
González, MV [1 ]
Castro, JM [1 ]
González, E [1 ]
Pérez, J [1 ]
Rodríguez, M [1 ]
Calleja, A [1 ]
Vilariño, JML [1 ]
机构
[1] Univ A Coruna, Ctr Invest Tecnol, EU Politecn, Dept Quim Analit,Lab Quim, Ferrol 15405, Spain
关键词
carbograph cartridge; polymeric cartridge; solid phase extraction; triazines;
D O I
10.1016/S0039-9140(02)00572-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Triazine herbicides form a wide group of substances that belong among the most common agrochemicals applied for pre- and post-emergence weed control. So, they can be found in the environment at trace level. In order to determine their concentrations in water samples by the usual analytical techniques, a preconcentration step is commonly necessary. In this paper, a simple analytical method for the quantification of eight triazines (three chlorotriazines, four methylthiotriazines and one methoxytriazine) in water samples by solid phase extraction-reversed phase liquid chromatography (LC) has been developed. LC shows good analytical performance for simultaneous multiple triazine analysis (repeatability < 2%, reproducibility < 3%), except for prometon (repeatability 5.52%, reproducibility 16%). The results, obtained by using carbograph and polymeric sorbents for solid phase extraction (SPE), have been compared. The limits of quantification achieved permit the application of the proposed SPE-LC method for the determination of eight triazines in water samples (0.0065-0.028 mug l(-1)). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:561 / 569
页数:9
相关论文
共 18 条
[1]   Monitoring of pesticides in river water based on samples previously stored in polymeric cartridges followed by on-line solid-phase extraction liquid chromatography diode array detection and confirmation by atmospheric pressure chemical ionization mass spectrometry [J].
Aguilar, C ;
Ferrer, I ;
Borrull, F ;
Marcé, RM ;
Barceló, D .
ANALYTICA CHIMICA ACTA, 1999, 386 (03) :237-248
[2]   EXTRACTION AND ISOLATION OF TRIAZINE HERBICIDES FROM WATER AND VEGETABLES BY A DOUBLE TRAP TANDEM SYSTEM [J].
BATTISTA, M ;
DICORCIA, A ;
MARCHETTI, M .
ANALYTICAL CHEMISTRY, 1989, 61 (09) :935-939
[3]   SIMULTANEOUS DETERMINATION OF TRIAZINES INCLUDING ATRAZINE AND THEIR MAJOR METABOLITES HYDROXYATRAZINE, DESETHYLATRAZINE, AND DEISOPROPYLATRAZINE IN NATURAL-WATERS [J].
BERG, M ;
MULLER, SR ;
SCHWARZENBACH, RP .
ANALYTICAL CHEMISTRY, 1995, 67 (11) :1860-1865
[4]   MULTIRESIDUE METHOD FOR PESTICIDES IN DRINKING-WATER USING A GRAPHITIZED CARBON-BLACK CARTRIDGE EXTRACTION AND LIQUID-CHROMATOGRAPHIC ANALYSIS [J].
DICORCIA, A ;
MARCHETTI, M .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :580-585
[5]   Determination of triazines in water samples by high-performance liquid chromatography with diode-array detection [J].
Dopico, MS ;
González, MV ;
Castro, JM ;
González, E ;
Pérez, J ;
Rodríguez, M ;
Calleja, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (09) :523-528
[6]   Determination and stability of pesticides in freeze-dried water samples by automated on-line solid-phase extraction followed by liquid chromatography with diode-array detection [J].
Ferrer, I ;
Barcelo, D .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :93-99
[7]  
HENNION MC, 2000, SAMPLE HANDLING TRAC, P4
[8]  
*ISO, 1998, 572511994 ISO AENOR
[9]   Pesticide monitoring of drinking water with the help of solid-phase extraction and high-performance liquid chromatography [J].
JunkerBuchheit, A ;
Witzenbacher, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :67-74
[10]  
Martin-Esteban A, 1998, QUIM ANAL, V17, P51