Randomised trial investigating effect of a novel nicotine delivery device (Eclipse) and a nicotine oral inhaler on smoking behaviour, nicotine and carbon monoxide exposure, and motivation to quit

被引:42
作者
Fagerström, KO
Hughes, JR
Rasmussen, T
Callas, PW
机构
[1] Smokers Informat Ctr & Fagerstrom Consulting, S-25452 Helsingborg, Sweden
[2] Univ Vermont, Dept Psychiat & Psychol, Burlington, VT USA
[3] Pharmacia & Upjohn Inc, Consumer Healthcare, Biostat & Data Management, Helsingborg, Sweden
[4] Univ Vermont, Biometry Facil, Coll Med, Burlington, VT 05405 USA
关键词
tobacco; nicotine; harm reduction; nicotine replacement;
D O I
10.1136/tc.9.3.327
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Objective-To monitor the effect of a novel nicotine delivery device that may produce fewer carcinogens (Eclipse) on cigarette smoking, carbon monoxide and nicotine concentrations, and motivation to give up smoking. The smoker's own brand of cigarette and a nicotine replacement product (Nicotrol inhaler) were used as comparisons. Design-After baseline data were recorded, smokers were randomised to either Eclipse or inhaler for two weeks and then switched to the other product for another two weeks. Thereafter a second baseline was obtained. Setting and participants-Fifty smokers were included and data are reported for the 40 with complete data sets. The smokers were not trying to quit but were interested in trying a new product to reduce their risk. They visited a smoking clinic 10 times during the six week period of the trial. intervention-No counselling to aid reduction by Eclipse or inhaler was given. Main outcome measures-At each visit smoking status and carbon monoxide concentrations were recorded. In half of the visits withdrawal symptoms, attitudes towards smoking, heart rate, and blood nicotine concentrations were also recorded. Results-Eclipse use decreased the number of cigarettes smoked per day (cpd) from 19.1 cpd at baseline to 2.1 cpd (p < 0.001), but increased carbon monoxide concentrations in parts per million (ppm) from 21.0 ppm to 33.0 ppm (p < 0.001). A similar decrease in cigarettes smoked per day was seen with the Nicotrol inhaler, from 19.1 cpd to 4.8 cpd (p < 0.001), but carbon monoxide decreased from 21.0 ppm to 12.7 ppm (p < 0.001). The blood nicotine concentration remained fairly stable with Eclipse, increasing slightly from 16.8 ng/ml to 18.0 ng/ml, while for the inhaler a significant drop was noted, from 16.8 ng/ml to 12.2 ng/ml (p < 0.002). Craving and withdrawal did not increase with Eclipse. Few significant adverse events occurred with Eclipse. Conclusions-Eclipse can dramatically decrease cigarette consumption without causing withdrawal symptoms or decreases in nicotine concentrations or motivation to quit altogether. Unlike the inhaler, Eclipse produces an increase in carbon monoxide concentration, Thus Eclipse may not be a safer cigarette.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 21 条
[1]   Cardiovascular toxicity of nicotine: Implications for nicotine replacement therapy [J].
Benowitz, NL ;
Gourlay, SG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) :1422-1431
[2]   PREMIER SMOKELESS CIGARETTES CAN BE USED TO DELIVER CRACK [J].
CONE, EJ ;
HENNINGFIELD, JE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1989, 261 (01) :41-41
[3]   CHEMICAL AND BIOLOGICAL STUDIES OF A CIGARETTE THAT HEATS RATHER THAN BURNS TOBACCO [J].
DEBETHIZY, JD ;
BORGERDING, MF ;
DOOLITTLE, DJ ;
ROBINSON, JH ;
MCMANUS, KT ;
RAHN, CA ;
DAVIS, RA ;
BURGER, GT ;
HAYES, JR ;
REYNOLDS, JH ;
HAYES, AW .
JOURNAL OF CLINICAL PHARMACOLOGY, 1990, 30 (08) :755-763
[4]  
Fagerstrom K O, 1997, Tob Control, V6, P311
[5]  
GIOVINO GA, 1996, SMOKING TOBACCO CONT, V7
[6]  
HEATHERTON TF, 1991, BRIT J ADDICT, V86, P1119
[7]  
Hughes JR, 1998, AM J PREV MED, V15, P78
[8]   Nicotine replacement: a new approach to reducing tobacco-related harm [J].
Jimenez-Ruiz, C ;
Kunze, M ;
Fagerstrom, KO .
EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (02) :473-479
[9]  
Jones B., 1989, DESIGN ANAL CROSS OV
[10]  
LUNELL E, 1995, EUR J CLIN PHARMACOL, V48, P235