Multilaboratory testing of thrombophilia: Current and past practice in Australasia as assessed through the Royal College of Pathologists of Australasia Quality Assurance Program for Hematology

被引:40
作者
Favaloro, EJ [1 ]
Bonar, R
Sioufi, J
Wheeler, M
Low, J
Aboud, M
Duncan, E
Smith, J
Exner, T
Lloyd, J
Marsden, K
机构
[1] Westmead Hosp, Inst Clin Pathol & Med Res, Dept Haematol, WSAHS, Westmead, NSW 2145, Australia
[2] Westmead Hosp, Inst Clin Pathol & Med Res, Charge Haematol Labs, Westmead, NSW 2145, Australia
[3] Westmead Hosp, Inst Clin Pathol & Med Res, Dept Haematol, Westmead, NSW 2145, Australia
[4] Westmead Hosp, Inst Clin Pathol & Med Res, RCPA Qual Assurance Program, Westmead, NSW 2145, Australia
关键词
Protein C; protein S; antithrombin; activated protein C resistance; lupus anticoagulant; laboratory assessment; quality control;
D O I
10.1055/s-2005-863805
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have conducted a series of multilaboratory surveys during the last 6 years to evaluate testing proficiency in the detection of congenital and acquired thrombophilia. For lupus anticoagulant (LA) testing, participant laboratories used a panel of tests, including activated partial thromboplastin time (aPTT; 100% of laboratories), kaolin clotting time (26 to 70%), and Russell's viper venom time (RVVT; 75 to 100%). Coefficients of variation (CVs) for assays ranged from 5 to 40%. RVVT assays appeared to be most sensitive and specific for detection of LA (fewer false-negatives or -positives), although laboratories performed best when they used a panel of tests. For congenital thrombophilia, tests evaluated comprised protein C (PC), protein S (PS), antithrombin (AT), and activated protein C resistance (APCR). Most participant laboratories performed PC using chromogenic (approximately 75%), or clot based (approximately 15%) assays, with few (< 10%) performing antigenic assessments. PS was most often assessed (approximately 60%) by immunological or antigenic assays, usually of free PS, or by functional or clot-based assays (approximately 40%). AT is usually assessed by functional chromogenic assays (approximately 95%). APCR was assessed using aPTT (approximately 50%) or RVVT (approximately 50%) clot-based assays, with the aPTT APCR typically performed using factor V-deficient plasma predilution, but the RVVT APCR typically performed without. Laboratories using the RVVT APCR generally performed better in detection of factor V Leiden-associated APCR, with the aPTT method group yielding higher false-negative and/or false-positive findings (approximately 5% of occasions). Some clot-based PC and PS assays appeared to be influenced by APCR status, and yielded lower apparent PC and PS levels with positive APC resistance. The overall error rate for PC, PS, and AT was approximately 2 to 8% (i.e., false-normal interpretations for deficient plasma or false-abnormal interpretations for normal plasma). The CVs for these assays ranged from 5 to 40%, with highest CVs typically obtained with PS assays.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 23 条
[1]  
Bertina RM, 2001, THROMB HAEMOSTASIS, V86, P92
[2]   A reduced sensitivity for activated protein C in the absence of factor V Leiden increases the risk of venous thrombosis [J].
de Visser, MCH ;
Rosendaal, FR ;
Bertina, RM .
BLOOD, 1999, 93 (04) :1271-1276
[3]  
Favaloro EJ, 1999, THROMB HAEMOSTASIS, V82, P1276
[4]   A multilaboratory peer assessment quality assurance program-based evaluation of anticardiolipin antibody, and beta2-glycoprotein I antibody testing [J].
Favaloro, EJ ;
Wong, RCW ;
Silvestrini, R ;
McEvoy, R ;
Jovanovich, S ;
Roberts-Thomson, P .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2005, 31 (01) :73-84
[5]  
Favaloro EJ, 1999, BRIT J BIOMED SCI, V56, P23
[6]   Laboratory diagnosis of von Willebrand disorder - Current practice in the Southern Hemisphere [J].
Favaloro, EJ ;
Bonar, R ;
Sioufi, J ;
Hertzberg, M ;
Street, A ;
Lloyd, J ;
Marsden, K .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (06) :882-893
[7]   Assessing the usefulness of anticardiolipin antibody assays - A cautious approach is suggested by high variation and limited consensus in multilaboratory testing [J].
Favaloro, EJ ;
Silvestrini, R .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2002, 118 (04) :548-557
[8]   A 9-year retrospective assessment of laboratory testing for activated protein C resistance: evolution of a novel approach to thrombophilia investigations [J].
Favaloro, EJ ;
Orsag, I ;
Bukuya, W ;
McDonald, D .
PATHOLOGY, 2002, 34 (04) :348-355
[9]  
Favaloro EJ, 1999, AM J CLIN PATHOL, V112, P712
[10]   Assessment of current diagnostic practice and efficacy in testing for von Willebrand's disorder: results from the second Australasian multi-laboratory survey [J].
Favaloro, EJ ;
Thom, J ;
Baker, R .
BLOOD COAGULATION & FIBRINOLYSIS, 2000, 11 (08) :729-737