Studies of the application of overoxidised polypyrrole films in anodic stripping voltammetry

被引:15
作者
Arrigan, DWM [1 ]
Lowens, MJ [1 ]
机构
[1] Univ Salford, Sci Res Inst, Div Chem Sci, Salford M5 4WT, Lancs, England
来源
ANALYTICAL COMMUNICATIONS | 1998年 / 35卷 / 02期
关键词
D O I
10.1039/a800111a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Overoxidised polypyrrole (OPPY) films have been evaluated for application in anodic stripping voltammetry (ASV) at mercury film electrodes (MFEs). The results presented indicate that such films possess the ability to prevent surfactant adsorption on the MFE surface and allow direct ASV determination of heavy metals in solutions containing proteins or other surfactants. This ability is attributed to the size-discriminating properties of OPPY which allow the small inorganic heavy metal ions to be transported across the polymer film while excluding the larger surfactant molecules.
引用
收藏
页码:61 / 62
页数:2
相关论文
共 13 条
[1]   ORGANIC ELECTROCHEMISTRY IN THE SOLID STATE-OVEROXIDATION OF POLYPYRROLE [J].
BECK, F ;
BRAUN, P ;
OBERST, M .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1987, 91 (09) :967-974
[2]  
BOND AM, 1984, ANAL CHIM ACTA, V162, P389, DOI 10.1016/S0003-2670(00)84263-4
[3]   TRACE-METAL ANALYSIS BY ANODIC-STRIPPING VOLTAMMETRY - EFFECT OF SORPTION BY NATURAL AND MODEL ORGANIC-COMPOUNDS [J].
BREZONIK, PL ;
BRAUNER, PA ;
STUMM, W .
WATER RESEARCH, 1976, 10 (07) :605-612
[4]   An ASIC-based system for stripping voltammetric determination of trace metals [J].
Desmond, D ;
Lane, B ;
Alderman, J ;
Hall, G ;
AlvarezIcaza, M ;
Garde, A ;
Ryan, J ;
Barry, L ;
Svehla, G ;
Arrigan, DWM ;
Schniffner, L .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :466-470
[5]   Prediction and characterization of the charge/size exclusion properties of over-oxidized poly(pyrrole) films [J].
Farrington, AM ;
Slater, JM .
ELECTROANALYSIS, 1997, 9 (11) :843-847
[6]   ANION-EXCLUDING POLYPYRROLE FILMS [J].
FREUND, M ;
BODALBHAI, L ;
BRAJTERTOTH, A .
TALANTA, 1991, 38 (01) :95-99
[7]   RAPID HIGH-PERFORMANCE ANALYTICAL PROCEDURE WITH SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF TOXIC TRACE-METALS IN URINE [J].
GOLIMOWSKI, J ;
VALENTA, P ;
STOEPPLER, M ;
NURNBERG, HW .
TALANTA, 1979, 26 (08) :649-656
[8]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM ;
BATLEY, GE .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1608-1614
[9]   ELECTROCHEMICAL PREPARATION AND ANALYTICAL APPLICATIONS OF ULTRATHIN OVEROXIDIZED POLYPYRROLE FILMS [J].
HSUEH, CC ;
BRAJTERTOTH, A .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2458-2464
[10]   Overoxidized polypyrrole-coated carbon fiber microelectrodes for dopamine measurements with fast-scan cyclic voltammetry [J].
Pihel, K ;
Walker, QD ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2084-2089