Near-field microwave imaging of biologically-based materials using a monopole transceiver system

被引:107
作者
Meaney, PM [1 ]
Paulsen, KD
Chang, JT
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Norris Cotton Canc Ctr, Dartmouth Hitchcock Med Ctr, Lebanon, NH 03755 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/22.654920
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A prototype monopole-transceiver microwave imaging system has been implemented, and initial single and multitarget imaging experiments involving biologically relevant property distributions have been conducted to evaluate its performance relative to a previously developed waveguide system. A new, simplified, but more effective calibration procedure has also been devised and tested. Results show that the calibration procedure leads to improvements which are independent of the type of radiator used, Specifically, data-model match is found to increase by 0.4 dB in magnitude and 4 degrees in phase for the monopoles and by 0.6 dB in magnitude and 7 degrees in phase for the waveguides (on average) on a per measurement basis when the new calibration procedure is employed, Enhancements are also found in the reconstructed images obtained with the monopole system relative to waveguides. Improvements are observed in: 1) the recovered object shape; 2) the uniformity of the background; 3) edge detection; and 4) target property value recovery. Analyses of reconstructed images also suggest that there is a systematic decrease of approximately 10% in the reconstruction errors for the monopole system over its waveguide counterpart in single-target experiments and as much as a 20% decrease in multitarget cases, Results indicate that these enhancements stem from a better data-model match for the monopoles relative to waveguides which Is consistent across the type of calibration procedure used, Comparisons of computations and measurements show an average improvement in data-model match of approximately 0.25 dB in magnitude and near 7 degrees in phase in favor of the monopoles in this regard. Beyond this apparent imaging performance enhancement, the monopole system offers economy-of-space and low construction-cost considerations along with computational advantages (as described herein) which make it a compelling choice as a radiator/receiver element around which to construct a clinically viable near-field microwave imaging system.
引用
收藏
页码:31 / 45
页数:15
相关论文
共 20 条
[1]  
[Anonymous], 1986, Medical Applications of Microwave Imaging
[3]   PLANAR MICROWAVE IMAGING CAMERA FOR BIO-MEDICAL APPLICATIONS - CRITICAL AND PROSPECTIVE ANALYSIS OF RECONSTRUCTION ALGORITHMS [J].
BOLOMEY, JC ;
PICHOT, C ;
GARBORIAUD, G .
RADIO SCIENCE, 1991, 26 (02) :541-549
[4]   ON THE USE OF REGULARIZATION TECHNIQUES IN NUMERICAL INVERSE-SCATTERING SOLUTIONS FOR MICROWAVE IMAGING APPLICATIONS [J].
CAORSI, S ;
CIARAMELLA, S ;
GRAGNANI, GL ;
PASTORINO, M .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1995, 43 (03) :632-640
[5]   RECONSTRUCTION OF DIELECTRIC PERMITTIVITY DISTRIBUTIONS IN ARBITRARY 2-D INHOMOGENEOUS BIOLOGICAL BODIES BY A MULTIVIEW MICROWAVE NUMERICAL-METHOD [J].
CAORSI, S ;
GRAGNANI, GL ;
PASTORINO, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :232-239
[6]   A MULTIVIEW MICROWAVE IMAGING-SYSTEM FOR 2-DIMENSIONAL PENETRABLE OBJECTS [J].
CAORSI, S ;
GRAGNANI, GL ;
PASTORINO, M .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1991, 39 (05) :845-851
[7]   Microwave imaging - Complex permittivity reconstruction with a Levenberg-Marquardt method [J].
Franchois, A ;
Pichot, C .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1997, 45 (02) :203-215
[8]  
JAOCHIMOWICZ N, 1991, IEEE T ANTENN PROPAG, V39, P1742
[9]   MEDICAL IMAGING WITH A MICROWAVE TOMOGRAPHIC SCANNER [J].
JOFRE, L ;
HAWLEY, MS ;
BROQUETAS, A ;
DELOSREYES, E ;
FERRANDO, M ;
ELIASFUSTE, AR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :303-312
[10]   FREQUENCY OPTIMIZATION FOR MICROWAVE IMAGING OF BIOLOGICAL TISSUES [J].
LIN, JC .
PROCEEDINGS OF THE IEEE, 1985, 73 (02) :374-375