Nonlinear dynamics of microvascular blood flow

被引:47
作者
Carr, RT
Lacoin, M
机构
[1] Univ New Hampshire, Dept Chem Engn, Durham, NH 03824 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA USA
关键词
microvascular networks; blood flow oscillations;
D O I
10.1114/1.1306346
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kiani ct al. (Kiani, M. F., A. R. Pries, L. L. Hsu, I. H. Sarelius, and G. R. Cokelet, Am. J. Physics. 266: H1822-H1828, 1994) suggested that blood velocity, hematocrit, and nodal pressures can oscillate spontaneously in large microvascular networks in the absence of biological control. This paper presents a model of blood flow in microvascular networks that shows the possibility of sustained spontaneous oscillations in small networks (less than 15 vessel segments). The paper explores mechanisms which cause spontaneous oscillations under some conditions and steady states under others. The existence of sustained oscillations in the absence of biological control provides alternative interpretations of dynamic behavior in the microcirculation. The model includes the Fahraeus-Lindqvist effect and plasma skimming but no biological control mechanisms. The model is a set of coupled nonlinear partial differential equations. The equations have been solved numerically with the direct marching numerical method of characteristics. The model shows steady-state fixed point and limit cycle dynamics (sometimes showing period doubling). Plasma skimming, and the Fahraeus-Lindqvist effect, along with arcade type topology are necessary for oscillations to occur. Depending on network parameters, nonoscillating, damped oscillating and sustaining oscillating dynamics have been demonstrated. Oscillations are damped when the residence time one of the vessels is large compared to the residence times for the other vessels. When the residence times for all vessels are comparable, sustained oscillations are possible. (C) 2000 Biomedical Engineering Society. [S0090-6964(00)01206-6].
引用
收藏
页码:641 / 652
页数:12
相关论文
共 30 条
[1]   PREDICTION OF BLOOD FLOW IN TUBES WITH DIAMETERS AS SMALL AS 29-MU [J].
BARBEE, JH ;
COKELET, GR .
MICROVASCULAR RESEARCH, 1971, 3 (01) :17-&
[2]   VASOMOTION FREQUENCY AND AMPLITUDE RELATED TO INTRALUMINAL PRESSURE AND TEMPERATURE IN THE WING OF THE INTACT, UNANESTHETIZED BAT [J].
BOUSKELA, E .
MICROVASCULAR RESEARCH, 1989, 37 (03) :339-351
[3]  
Carr Russell T., 1995, Microcirculation (New York), V2, P345, DOI 10.3109/10739689509148278
[4]   A commentary on the "In vivo viscosity law" [J].
Cokelet, GR .
BIORHEOLOGY, 1997, 34 (4-5) :363-367
[5]  
COKELET GR, 1986, MICROVASCULAR NETWOR, P155
[6]   The viscosity of the blood in narrow capillary tubes [J].
Fahraeus, R ;
Lindqvist, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1931, 96 (03) :562-568
[7]   NONUNIFORM RED-CELL DISTRIBUTION IN 20 TO 100 MU-M BIFURCATIONS [J].
FENTON, BM ;
CARR, RT ;
COKELET, GR .
MICROVASCULAR RESEARCH, 1985, 29 (01) :103-126
[8]   ANALYSIS OF THE EFFECTS OF MEASURED WHITE BLOOD-CELL ENTRANCE TIMES ON HEMODYNAMICS IN A COMPUTER-MODEL OF A MICROVASCULAR BED [J].
FENTON, BM ;
WILSON, DW ;
COKELET, GR .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1985, 403 (04) :396-401
[9]  
Fung Y.C., 1996, Biomechanics: Circulation
[10]  
GOLDSMITH HL, 1971, FED PROC, V30, P1578