As an inexpensive, simple, and low-solvent consuming extraction technique, the suitability of solid-phase microextraction (SPME) with polydimethylsiloxane (PDMS) sorbent was investigated as a quantitative method for sampling gaseous organophosphate triesters in air. These compounds have become ubiquitous in indoor air, because of their widespread use as additive flame retard ants/plasticizers in various indoor materials. Results obtained by sampling these compounds at controlled air concentrations using SPME and active sampling on glass fibre filters were compared to evaluate the method. A constant linear airflow of 10 cm s(-1) over the fibres was applied to increase the extraction rate. For extraction of triethyl phosphate with a 100-mum PDMS fibre, equilibrium was achieved after 8 h. The limit of detection was determined to be less than 10 pg m(-3). The PDMS-air partition coefficients, K-fs, for the individual organophosphate triesters were determined to be in the range 5-60x10(6) at room temperature (22-23degreesC). Air measurements were performed utilising the determined coefficients for quantification. In samples taken from a lecture room four different airborne organophosphate esters were identified, the most abundant of which was tris(chloropropyl) phosphate, at the comparatively high level of 1.1 mug m(-3). The results from SPME and active sampling had comparable repeatability (RSD less than 17%), and the determined concentrations were also similar. The results suggest that the investigated compounds were almost entirely associated with the gaseous phase at the time and place sampled.