Suite of three protein crystallography beamlines with single superconducting bend magnet as the source

被引:80
作者
MacDowell, AA
Celestre, RS
Howells, M
McKinney, W
Krupnick, J
Cambie, D
Domning, EE
Duarte, RM
Kelez, N
Plate, DW
Cork, CW
Earnest, TN
Dickert, J
Meigs, G
Ralston, C
Holton, JM
Alber, T
Berger, JM
Agard, DA
Padmore, HA
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Adv Light Source, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Engn, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Dept Mol & Cell Biol, Berkeley, CA 94720 USA
[4] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
X-ray beamline; protein crystallography; superbend; invar mirror; double-crystal monochromator;
D O I
10.1107/S0909049504024835
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the Advanced Light Source, three protein crystallography beamlines have been built that use as a source one of the three 6 T single-pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single-pole superconducting bend magnets enables the development of a hard X-ray program on a relatively low-energy 1.9 GeV ring without taking up insertion-device straight sections. The source is of relatively low power but, owing to the small electron beam emittance, it has high brightness. X-ray optics are required to preserve the brightness and to match the illumination requirements for protein crystallography. This was achieved by means of a collimating premirror bent to a plane parabola, a double-crystal monochromator followed by a toroidal mirror that focuses in the horizontal direction with a 2:1 demagnification. This optical arrangement partially balances aberrations from the collimating and toroidal mirrors such that a tight focused spot size is achieved. The optical properties of the beamline are an excellent match to those required by the small protein crystals that are typically measured. The design and performance of these new beamlines are described.
引用
收藏
页码:447 / 455
页数:9
相关论文
共 19 条
[1]   The macromolecular crystallography facility at the advanced light source [J].
Earnest, T ;
Padmore, H ;
Cork, C ;
Behrsing, R ;
Kim, SH .
JOURNAL OF CRYSTAL GROWTH, 1996, 168 (1-4) :248-252
[2]  
FREUND A, 2000, COMMUNICATION
[3]   Radiation damage to crystalline biological molecules: current view [J].
Garman, E ;
Nave, C .
JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 :327-328
[4]   Characterization of conditions required for x-ray diffraction experiments with protein microcrystals [J].
Glaeser, R ;
Facciotti, M ;
Walian, P ;
Rouhani, S ;
Holton, J ;
MacDowell, A ;
Celestre, R ;
Cambie, D ;
Padmore, H .
BIOPHYSICAL JOURNAL, 2000, 78 (06) :3178-3185
[6]   A MEASUREMENT OF THE LIGHT YIELD OF COMMON INORGANIC SCINTILLATORS [J].
HOLL, I ;
LORENZ, E ;
MAGERAS, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :105-109
[7]   Theory and practice of elliptically bent x-ray mirrors [J].
Howells, MR ;
Cambie, D ;
Duarte, RM ;
Irick, S ;
MacDowell, AA ;
Padmore, HA ;
Renner, TR ;
Rah, S ;
Sandler, R .
OPTICAL ENGINEERING, 2000, 39 (10) :2748-2762
[8]   Nickel-plated invar mirrors for synchrotron-radiation beam lines [J].
Howells, MR ;
Burt, P ;
Cambie, D ;
Duarte, R ;
Franck, A ;
Irick, S ;
MacDowell, A ;
MacGill, D ;
Paquin, R ;
Plate, D .
X-RAY MIRRORS, CRYSTALS, AND MULTILAYERS II, 2002, 4782 :94-103
[9]  
HOWELLS MR, 1999, LSBL529 ADV LIGHT SO
[10]  
HOWELLS MR, 2004, UNPUB J SYNCHROTRON