A comparison of techniques for modelling data with non-linear structure

被引:9
作者
Stordrange, L
Kvalheim, OM
Hassel, PA
Malthe-Sorenssen, D
Libnau, FO
机构
[1] Univ Bergen, Dept Chem, N-5007 Bergen, Norway
[2] Newcastle Univ, Dept Chem & Proc Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[3] Amersham Hlth AS, N-4521 Spangereid, Norway
关键词
near infrared spectroscopy (NIR); multivariate calibration; PLS; locally weighted regression (LWR); quadratic PLS (QPLS);
D O I
10.1255/jnirs.354
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Partial least squares (PLS) is a powerful tool for multivariate linear regression. But what if the data show a nonlinear structure? Near infrared spectra from a pharmaceutical process were used as a case study. An ANOVA test revealed that the data are well described by a 2(nd) order polynomial. This work investigates the application of regression techniques that account for slightly non-linear data. The regression techniques investigated are: linearising data by applying transformations, local PLS, i.e. splitting of data, and quadratic PLS. These models were compared with ordinary PLS and principal component regression (PCR). The predictive ability of the models was tested on an independent data set acquired a year later. Using the knowledge of non-linear pattern and important spectral regions, simpler models with better predictive ability can be obtained.
引用
收藏
页码:55 / 70
页数:16
相关论文
共 23 条
[1]   PLS regression methods [J].
Höskuldsson, Agnar .
Journal of Chemometrics, 1988, 2 (03) :211-228
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]  
Antti H, 1996, J CHEMOMETR, V10, P591
[4]   Non-linear projection to latent structures revisited: the quadratic PLS algorithm [J].
Baffi, G ;
Martin, EB ;
Morris, AJ .
COMPUTERS & CHEMICAL ENGINEERING, 1999, 23 (03) :395-411
[5]   Calibration in non-linear near infrared reflectance spectroscopy:: a comparison of several methods [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pagès, J .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :207-214
[6]   Comparison of multivariate calibration techniques applied to experimental NIR data sets [J].
Centner, V ;
Verdú-Andrés, J ;
Walczak, B ;
Jouan-Rimbaud, D ;
Despagne, F ;
Pasti, L ;
Poppi, R ;
Massart, DL ;
de Noord, OE .
APPLIED SPECTROSCOPY, 2000, 54 (04) :608-623
[7]   Real time quantitation of a chemical reaction by fiber optic near-infrared spectroscopy [J].
Coffey, C ;
Cooley, BE ;
Walker, DS .
ANALYTICA CHIMICA ACTA, 1999, 395 (03) :335-341
[8]   The Mahalanobis distance [J].
De Maesschalck, R ;
Jouan-Rimbaud, D ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) :1-18
[9]  
Howard WW, 1998, APPL SPECTROSC, V52, P17
[10]   OPTIMIZED SCALING - A NOVEL-APPROACH TO LINEAR CALIBRATION WITH CLOSED DATA SETS [J].
KARSTANG, TV ;
MANNE, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1992, 14 (1-3) :165-173