A novel approach to determine optimum switching frequency of a conventional adsorption chiller

被引:31
作者
Alam, KCA [1 ]
Kang, YT [1 ]
Saha, BB [1 ]
Akisawa, A [1 ]
Kashiwagi, T [1 ]
机构
[1] Tokyo Univ A&T, Dept Mech Syst Engn, Koganei, Tokyo 1848588, Japan
关键词
D O I
10.1016/S0360-5442(03)00064-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article investigates the effect of design parameters on the switching frequency of a conventional adsorption chiller with silica gel as adsorbent and water as adsorbate. It is well known that as the cycle time lengthens, the coefficient of performance (COP) rises but the cooling capacity lowers. Optimum cycle time is dependendent on the requirements of COP and cooling capacity. A novel simulation technique that introduces a profit function is employed to determine the optimum switching frequency of an adsorption refrigeration system. The results show that optimum switching frequency is very sensitive to the heat exchanger's design parameters. The design parameters are characterized by the number of transfer unit, NTU, the Biot number of adsorbent bed, Bi, the aspect ratio, AR, the ratio of the heat exchanger thickness to the radius of the fluid channel Hr, the fluid alpha number, alpha(f-a) and the inert material alpha number, alpha(m-a). The optimum switching frequency increases with the increase of NTU, Hr and with the decrease of Bi, AR, alpha(m-a) and alpha(f-a) . (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1021 / 1037
页数:17
相关论文
共 22 条
[1]   Heat exchanger design effect on the system performance of silica gel adsorption refrigeration systems [J].
Alam, KCA ;
Saha, BB ;
Kang, YT ;
Akisawa, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (24) :4419-4431
[2]  
AMAR NB, 1996, APPL THERM ENG, V6, P405
[3]  
BEIJER HA, 1993, P INT ABS HEAT PUMP, V31, P449
[4]  
Boelman EC, 1995, ASHRAE TRAN, V101, P358
[5]   AIR DRYING BY PRESSURE SWING ADSORPTION [J].
CHIHARA, K ;
SUZUKI, M .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1983, 16 (04) :293-299
[6]   Modeling the performance of two-bed, silica gel-water adsorption chillers [J].
Chua, HT ;
Ng, KC ;
Malek, A ;
Kashiwagi, T ;
Akisawa, A ;
Saha, BB .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (03) :194-204
[7]  
Critoph RE, 1988, P INT C POMP CHAL CH, P202
[8]   EXPERIMENTAL-STUDY OF CASCADING ADSORPTION CYCLES [J].
DOUSS, N ;
MEUNIER, F .
CHEMICAL ENGINEERING SCIENCE, 1989, 44 (02) :225-235
[9]   Effects of adsorbent conductivity and permeability on the performance of a solid sorption heat pump [J].
Ellis, MW ;
Wepfer, WJ .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1999, 121 (01) :51-59
[10]   A 2-TEMPERATURE MODEL OF THE REGENERATIVE SOLID-VAPOR HEAT-PUMP [J].
FULLER, TA ;
WEPFER, WJ ;
SHELTON, SV ;
ELLIS, MW .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1994, 116 (04) :297-304