Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients

被引:69
作者
Kulkarni, A [1 ]
Saxena, M [1 ]
Price, G [1 ]
O'Leary, MJ [1 ]
Jacques, T [1 ]
Myburgh, JA [1 ]
机构
[1] St George Hosp, Dept Intens Care Med, Sydney, NSW 2217, Australia
关键词
measurement; blood glucose; intensive care; hypoglycaemia; blood gas analysis;
D O I
10.1007/s00134-004-2500-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To analyse agreement between two methods for blood glucose measurement in intensive care patients: capillary blood using a reagent strip and glucometer with arterial blood using a blood gas analyser. Design and setting: Prospective, single-centre, observational study in a 12-bed tertiary referral intensive care unit. Measurements: Blood glucose levels were measured in consecutive patients using simultaneous measurements of capillary blood samples using glucometry and from a multielectrode arterial blood gas analyser. An a priori subgroup of patients with tissue hypoperfusion was identified ( defined as systolic blood pressure < 90 mmHg or vasopressor dependency). A total of 493 paired measurements were obtained; 75 of these were from patients with systemic hypoperfusion. Results: Overall, the mean difference ( bias) was 0.12 mmol/l (2.15 mg/dl) and precision 0.77 mmol/l (13.8 mg/dl); 95% limits of agreement were - 0.14 and 1.66 mmol/ l (- 2.5 and 29.8 mg/dl). In patients with systemic hypoperfusion the bias was 0.24 mmol/l (4.0 mg/dl) and precision 0.9 mmol/l (16.2 mg/ dl); 95% limits of agreement - 2.05 and 1.58 mmol/l (36.8 and 28.4 mg/ dl). Conclusions: In a general population of intensive care patients, there is statistical agreement between blood glucose measured from capillary blood glucometry and arterial blood gas analysis. However, in patients with systemic hypoperfusion, the accuracy of agreement between these two measurement techniques may be such that that biochemical hypoglycaemia (< 2.5 mmol/ l, 44.9 mg/ dl) may go undetected if used interchangeably.
引用
收藏
页码:142 / 145
页数:4
相关论文
共 10 条
[1]   FINGERSTICK GLUCOSE DETERMINATION IN SHOCK [J].
ATKIN, SH ;
DASMAHAPATRA, A ;
JAKER, MA ;
CHOROST, MI ;
REDDY, S .
ANNALS OF INTERNAL MEDICINE, 1991, 114 (12) :1020-1024
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Glycemic control in the ICU: a multicenter survey [J].
McMullin, J ;
Brozek, J ;
Jaeschke, R ;
Hamielec, C ;
Dhingra, V ;
Rocker, G ;
Freitag, A ;
Gibson, J ;
Cook, D .
INTENSIVE CARE MEDICINE, 2004, 30 (05) :798-803
[4]  
Sylvain H F, 1995, Am J Crit Care, V4, P44
[5]  
Tang Z, 2000, Diabetes Technol Ther, V2, P349, DOI 10.1089/15209150050194215
[6]  
Tang ZP, 2000, ARCH PATHOL LAB MED, V124, P1135
[7]  
Tang ZP, 2000, ARCH PATHOL LAB MED, V124, P577
[8]   ACCURACY OF FINGERSTICK GLUCOSE DETERMINATION IN PATIENTS RECEIVING CPR [J].
THOMAS, SH ;
GOUGH, JE ;
BENSON, N ;
AUSTIN, PE ;
STONE, CK .
SOUTHERN MEDICAL JOURNAL, 1994, 87 (11) :1072-1075
[9]  
TIMOTHY WE, 2001, NEW ENGL J MED, V345, P1417
[10]   Intensive insulin therapy in critically ill patients. [J].
Van den Berghe, G ;
Wouters, P ;
Weekers, F ;
Verwaest, C ;
Bruyninckx, F ;
Schetz, M ;
Vlasselaers, D ;
Ferdinande, P ;
Lauwers, P ;
Bouillon, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (19) :1359-1367