Kinetic spectrophotometric determination of formaldehyde in fabric and air by sequential injection analysis

被引:18
作者
Feng, SL
Fan, J
Wang, AJ
Chen, XG [1 ]
Hui, ZD
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Peoples R China
[2] Henan Normal Univ, Dept Educ, Key Lab Environm Sci & Engn, Xinxiang, Peoples R China
[3] Henan Normal Univ, Sch Chem & Environm Sci, Xinxiang, Peoples R China
关键词
formaldehyde; sequential injection analysis; spectrophotometry; fabric; air;
D O I
10.1081/AL-200031126
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A kinetic method for measuring formaldehyde by sequential injection analysis (SIA) with spectrophotometric detection was developed for the first time. The method was based on the inhibitory effect of formaldehyde on the ethyl green (EG)-sulfite reaction. The linear range for formaldehyde was 1.0-20.0 mug mL(-1); the detection limit was 0.020 mug mL(-1). The measurement rate was 130 sec, thus allowing to analyze 27 samples per hour, the total reagent consumption in a cyclical procedure is only 240 muL. The method was applied to the determination of formaldehyde in fabric and air, and compared with acetyl acetone spectrophotometric method.
引用
收藏
页码:2545 / 2555
页数:11
相关论文
共 30 条
[1]   SPECTROPHOTOMETRIC DETERMINATION OF FORMALDEHYDE [J].
ALJABARI, G ;
JASELSKIS, B .
TALANTA, 1988, 35 (08) :655-657
[2]   DETERMINATION OF FORMALDEHYDE IN GAS MIXTURES BY CHROMOTROPIC ACID METHOD [J].
ALTSHULLER, A ;
MILLER, DL ;
SLEVA, SF .
ANALYTICAL CHEMISTRY, 1961, 33 (04) :621-+
[3]   QUANTITATIVE-DETERMINATION OF FORMALDEHYDE IN AIR USING THE ACETYLACETONE METHOD [J].
BISGAARD, P ;
MOLHAVE, L ;
RIETZ, B ;
WILHARDT, P .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1983, 16 (17-1) :1457-1468
[4]  
CHRISTIAN GD, 1994, ANAL CHEM, P34
[5]   FAST FLUOROMETRIC FLOW-INJECTION ANALYSIS OF FORMALDEHYDE IN ATMOSPHERIC WATER [J].
DONG, S ;
DASGUPTA, PK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1987, 21 (06) :581-588
[6]   Sensitive reaction rate method for the determination of low levels of formaldehyde with photometric detection [J].
Ensafi, AA ;
Abassi, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (04) :376-379
[7]   Determination of formaldehyde traces in fabric and in indoor air by a kinetic fluorimetric method [J].
Fan, J ;
Tang, YJ ;
Feng, SL .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2002, 82 (06) :361-367
[8]   Determination of formaldehyde in liquid, solid and semisolid pharmaceuticals and cosmetics by flow injection-pervaporation [J].
Gámiz-Gracia, L ;
de Castro, MDL .
ANALYST, 1999, 124 (07) :1119-1121
[9]  
GAO H, 2001, YINRAN, V29, P46
[10]   Synthesis and application of 4-(N,N-dimethylaminosulfonyl)-7-N-methylhydrazino-2,1,3-benzoxadiazole (MDBDH) as a new derivatizing agent for aldehydes [J].
Jachmann, N ;
Karst, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (01) :47-53