Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty

被引:18
作者
Castoldi, Filippo
Rossi, Roberto
La Russa, Massimo
Sibelli, Pierro
Rossi, Paolo
Ranawat, Amar S.
机构
[1] Lenox Hill Hosp, Ranawat Orthoped Ctr, Ranawat Orthopaed Res Fdn, New York, NY 10021 USA
[2] Univ Turin, Sch Med, Mauriziano Umberto I Hosp, Dept Orthopaed & Traumatol 3, Turin, Italy
关键词
ABG; polyethylene; total hip arthroplasty; survivorship;
D O I
10.1016/j.arth.2006.05.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Anatomique Benoist Girard (ABG) I total hip arthroplasty has been widely used in Europe since 1989. Two recent midterm reports have shown high rates of component failure secondary to polyethylene wear. To further investigate this issue, our study prospectively follows 157 consecutive primary total hip arthroplasties using the ABG I prosthesis at an average follow-up of 10 years. Clinical outcomes have been excellent, although the incidence of thigh pain was 7.2%. Radiographic evaluation of the cup showed eccentric polyethylene wear in 93.6% of the patients. The average polyethylene linear wear was 2.40 mm, whereas the average annual wear rate was 0.25 mm/y. There were 7 hips (5.6%) with severe periacetabular osteolysis. Nine revisions were performed for loosening or wear. The overall component survival rate was 92.6%. The,overall survival rate was 92.6% (confidence interval, 78.55-96.47) for the acetabular component and 96.3% (confidence interval, 85.67-100) for the femoral component. Although the clinical and radiographic results of the ABG I total hip arthroplasty in this series have been acceptable, high rates of polyethylene wear, most likely related to sterilization by gamma-irradiation in air, have been the limiting factor in the long-term success of this design.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 27 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
CATASTROPHIC FAILURE OF THE POLYETHYLENE LINER OF UNCEMENTED ACETABULAR COMPONENTS [J].
BERRY, DJ ;
BARNES, CL ;
SCOTT, RD ;
CABANELA, ME ;
POSS, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :575-578
[3]
High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses - 65 hips in 56 young patients followed for 5-9 years [J].
Blacha, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (03) :276-282
[4]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]
CALLAGHAN JJ, 1995, CLIN ORTHOP RELAT R, V317, P14
[6]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[7]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]
Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis [J].
Dowd, JE ;
Sychterz, CJ ;
Young, AM ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) :1102-1107
[9]
Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty [J].
Duffy, P ;
Sher, JL ;
Partington, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01) :34-38
[10]
Garcia Araujo C, 1998, J Arthroplasty, V13, P660, DOI 10.1016/S0883-5403(98)80010-7