Biocompatibility of heparin-coated extracorporeal bypass circuits: New heparin bonded Bioline system

被引:45
作者
Tayama, E [1 ]
Hayashida, N [1 ]
Akasu, K [1 ]
Kosuga, T [1 ]
Fukunaga, S [1 ]
Akashi, H [1 ]
Kawara, T [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 8300011, Japan
关键词
Bioline; cardiopulmonary bypass; heparin coating; biocompatibility;
D O I
10.1046/j.1525-1594.2000.06615.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biocompatibility of a new type of heparin-coated cardiopulmonary bypass equipment, the Bioline, was evaluated in coronary artery bypass surgery cases. The heparin-coated (H) group (n = 15; Quadrox Bioline oxygenator/reservior and Carmeda BioMedicus BP-80 centrifugal pump) was compared with the nonheparin-coated (N) group (n = 12, uncoated, otherwise similar oxygenator, centrifugal pump, tubing, and filter set). Both groups used full systemic heparinization. The peak values of neutrophil elastase, C3a, IL-6, and IL-8 at 2 h after cardiopulmonary bypass (CPB), and C3a levels at the end of CPB and at 2 h after CPB were significantly reduced in the PI group compared with those of the N group. However, no statistically significant intergroup differences were observed in thrombin-antithrombin complex, D-dimer, beta-thromboglobulin, or platelet factor-4. No significant differences were observed in hemostasis time, postoperative 12 h blood loss, required amount of blood transfusion, or intubation time. In conclusion, the Bioline demonstrated partially improved biocompatibility, in terms of leukocyte and complement activation, and proinflammatory cytokine production. However, it did not improve platelet activation, coagulation, or fibrinolysis cascade under full systemic heparinization. As a result, the clinical beneficial impact seemed to be the minimum.
引用
收藏
页码:618 / 623
页数:6
相关论文
共 23 条
[1]  
Aldea GS, 1996, ANN THORAC SURG, V62, P410, DOI 10.1016/0003-4975(96)00249-4
[2]  
BADER KE, 1997, CANADIAN PERFUSION C, V9, P9
[3]  
BOONSTRA PW, 1994, J THORAC CARDIOV SUR, V107, P289
[4]  
BOROWIEC J, 1992, J THORAC CARDIOV SUR, V104, P642
[5]   INFLAMMATORY RESPONSE TO CARDIOPULMONARY BYPASS [J].
BUTLER, J ;
ROCKER, GM ;
WESTABY, S .
ANNALS OF THORACIC SURGERY, 1993, 55 (02) :552-559
[6]  
Casey LC, 1993, ANN THORAC SURG, V56, P92
[7]   BLOOD-SURFACE INTERACTIONS DURING CARDIOPULMONARY BYPASS [J].
EDMUNDS, LH .
JOURNAL OF CARDIAC SURGERY, 1993, 8 (03) :404-410
[8]   REDUCED COMPLEMENT AND GRANULOCYTE ACTIVATION WITH HEPARIN-COATED CARDIOPULMONARY BYPASS [J].
FOSSE, E ;
MOEN, O ;
JOHNSON, E ;
SEMB, G ;
BROCKMEIER, V ;
MOLLNES, TE ;
FAGERHOL, MK ;
VENGE, P .
ANNALS OF THORACIC SURGERY, 1994, 58 (02) :472-477
[9]  
GORMAN RC, 1996, J THORAC CARDIOVASC, V11, P1
[10]   HEPARIN-COATED CIRCUITS REDUCE THE INFLAMMATORY RESPONSE TO CARDIOPULMONARY BYPASS [J].
GU, YJ ;
VANOEVEREN, W ;
AKKERMAN, C ;
BOONSTRA, PW ;
HUYZEN, RJ ;
WILDEVUUR, CRH .
ANNALS OF THORACIC SURGERY, 1993, 55 (04) :917-922