Fast separation liquid chromatography-tandem mass spectrometry for the confirmation and quantitative analysis of avermectin residues in food

被引:50
作者
Hernando, M. D.
Suarez-Barcena, J. M.
Bueno, M. J. M.
Garcia-Reyes, J. F.
Fernandez-Alba, A. R. [1 ]
机构
[1] Univ Almeria, Dept Analyt Chem, Almeria 04120, Spain
[2] Food & Environm Anal Lab, Seville 41220, Spain
关键词
avermectin residues; food; confirmation; quantification; LC-MS; CHEMICAL-IONIZATION; MOXIDECTIN RESIDUES; CITRUS-FRUITS; ABAMECTIN; IVERMECTIN; LIVER; MATRICES; MILK;
D O I
10.1016/j.chroma.2007.02.120
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new residue analytical method for the confirmation and quantification of avermectin residues in food is described in this article. This method allows a fast analysis for the determination of avermectin residues, abamectin (ABM), ivermectin (IVM), emamectin benzoate (EMA) and doramectin (DOR) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Separation was performed using a short column of 1.8 mu m particle size. The hybrid quadrupole/linear ion trap (QqQ(LIT)) system via the linearly accelerating (LINAC) high-pressure collision cell, allows the MS detection in multiple reaction monitoring (MRM) mode operating in fast scan acquisition times. The effect of reduced dwell times on mass spectral quality and sensitivity is evaluated in this study. For quantitative purposes, the influence of dwell time on S/N ratio and peak area was observed. ABM, lVM, EMA and DOR show an increased trend of peak area and S/N ratio, when dwell times are of 50 ms against 10-20 ms, suited when the number of compounds to be analyzed is higher. The sensitivity achieved by using the LC-MS/MS system is enough for the confirmation of avermectin residues in the selected commodities (salmon muscle and pepper) at trace concentration levels (sub-mu g/kg and mu g/kg) and therefore a sample pre-concentration step was not necessary. The instrumental limits of quantification (ILQ) are in the range of 0.15-5 ppb. Samples were extracted by solid-liquid extraction (SLE) procedure using acetonitrile, and cleaned-up using alumina. The average recoveries obtained were acceptable (80-95%). The calibration curves were linear over the working range from ILQs to 500 mu g/kg. For the quantitative analysis, matrix-matched calibration and dilution of SLE extracts was proven as reliable alternative to compensate matrix-effects and for its feasible application in routine analysis. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 73
页数:12
相关论文
共 24 条
[1]   Review of methodology for the determination of macrocyclic lactone residues in biological matrices [J].
Danaher, Martin ;
Howells, Laurence C. ;
Crooks, Steven R. H. ;
Cerkvenik-Flajs, Vesna ;
O'Keefe, Michael .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (02) :175-203
[2]   Determination of abamectin residues in fruits and vegetables by high-performance liquid chromatography [J].
Diserens, H ;
Henzelin, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 833 (01) :13-18
[3]  
European Medicines Agency EMEA, 2006, EMEACVMP2832332006
[4]  
European Medicines Agency EMEA, 2004, EMEACVMP91504FINAL
[5]  
European Medicines Agency EMEA, 2003, EMEACVMP86303FINAL
[6]  
European Medicines Agency EMEA, 2002, EMEACVMP83802FINAL
[7]  
FernandezAlba AR, 2005, COMP ANAL C, V43, P1
[8]   Determination of pesticide residues in olives and olive oil by matrix solid-phase dispersion followed by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry [J].
Ferrer, C ;
Gómez, MJ ;
García-Reyes, JF ;
Ferrer, I ;
Thurman, EM ;
Fernández-Alba, AR .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1069 (02) :183-194
[9]   Evaluation of different quantitative approaches for the determination of noneasily ionizable molecules by different atmospheric pressure interfaces used in liquid chromatography tandem mass spectrometry:: Abamectin as case of study [J].
Grimalt, S ;
Pozo, OJ ;
Marín, JM ;
Sancho, JV ;
Hernández, F .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (10) :1619-1630
[10]   PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH NEGATIVE-ION CHEMICAL IONIZATION FOR THE CONFIRMATION OF IVERMECTIN RESIDUE IN BOVINE-MILK AND LIVER [J].
HELLER, DN ;
SCHENCK, FJ .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (03) :184-193