Accurate and sensitive measurements of pO2 in vivo using low frequency EPR spectroscopy:: How to confer biocompatibility to the oxygen sensors

被引:37
作者
Gallez, B
Mäder, K
机构
[1] Univ Catholique Louvain, Lab Med Chem & Radiopharm, B-1200 Brussels, Belgium
[2] Univ Catholique Louvain, Lab Biomed Magnet Resonance, B-1200 Brussels, Belgium
[3] Free Univ Berlin, Dept Pharmaceut Sci, D-1000 Berlin, Germany
关键词
EPR; ESR; in vivo; oxygen; encapsulation; free radicals;
D O I
10.1016/S0891-5849(00)00405-6
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Within the last few years, there has been a significant amount of progress using EPR oximetry, which has resulted in the availability of instrumentation and paramagnetic materials capable of measuring pO(2) in tissues with an accuracy and sensitivity comparable to or greater than that available by any other method. While the results obtained with EPR so far indicate that criteria for the measurements of pO(2)-such as accuracy, sensitivity, repeatability, and noninvasiveness-can be met, some of the paramagnetic materials with optimum spectroscopic properties (i.e., strong simple signals which are appropriately responsive to changes in pO(2)) may have some undesirable interactions with tissues, causing reactions with and/or losing responsiveness to oxygen. In this paper, several approaches are discussed, such as encapsulation procedures, which can result in the availability of oxygen-sensitive materials in a suitable configuration for long-term studies (absence of toxicity and preservation of the responsiveness to oxygen). (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1078 / 1084
页数:7
相关论文
共 24 条
[1]   EFFECTS OF OXYGEN ON THE METABOLISM OF NITROXIDE SPIN LABELS IN CELLS [J].
CHEN, K ;
GLOCKNER, JF ;
MORSE, PD ;
SWARTZ, HM .
BIOCHEMISTRY, 1989, 28 (06) :2496-2501
[2]   Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry [J].
Clarkson, RB ;
Odintsov, BM ;
Ceroke, PJ ;
Ardenkjaer-Larsen, JH ;
Fruianu, M ;
Belford, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (07) :1907-1920
[3]  
CLARKSON RB, 1999, INT WORKSH TECHN BIO, P29
[4]   Small particles of fusinite and carbohydrate chars coated with aqueous soluble polymers:: Preparation and applications for in vivo EPR oximetry [J].
Gallez, B ;
Debuyst, R ;
Dejehet, F ;
Liu, KJ ;
Walczak, T ;
Goda, F ;
Demeure, R ;
Taper, H ;
Swartz, HM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) :152-159
[5]   Development of biocompatible implants of fusinite for in vivo EPR oximetry [J].
Gallez, B ;
Debuyst, R ;
Liu, KJ ;
Demeure, R ;
Dejehet, F ;
Swartz, HM .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1996, 4 (01) :71-75
[6]  
Gallez B, 1999, MAGNET RESON MED, V42, P193, DOI 10.1002/(SICI)1522-2594(199907)42:1<193::AID-MRM25>3.0.CO
[7]  
2-C
[8]   Use of nitroxides for assessing perfusion, oxygenation, and viability of tissues: In vivo EPR and MRI studies [J].
Gallez, B ;
Bacic, G ;
Goda, F ;
Jiang, JJ ;
OHara, JA ;
Dunn, JF ;
Swartz, HM .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :97-106
[9]  
GALLEZ B, 1999, INT WORKSH TECHN BIO, P31
[10]   INVIVO OXIMETRY USING A NITROXIDE-LIPOSOME SYSTEM [J].
GLOCKNER, JF ;
CHAN, HC ;
SWARTZ, HM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) :123-133